{"product_id":"emerson-se4302t02-deltav-do-24v-dc-isolated-charm-module","title":"EMERSON SE4302T02 DeltaV DO 24V DC Isolated CHARM Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSE4302T02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEMERSON DeltaV™\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a digital output (DO) CHARM module engineered for 24 V DC inductive load control. Designed for installation directly in the field, it eliminates the need for traditional marshalling cabinets and complex cross-wiring, reducing installation time, wiring points, and potential failure risks. Its isolated output channels provide reliable performance while protecting downstream circuits.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports 24 V DC inductive loads with 1.0 A continuous output and 2.0 A inrush for under 100 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable output behavior: momentary output or continuous pulse\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGalvanically isolated output channel, factory-tested to 1000 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in field circuit protection: 4 A current limiting with thermal shutdown and automatic reset\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecommended external fuse at power source for additional safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCHARM power requirement: 22 mA max @ 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeat dissipation: 0.46 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDirect field installation minimizes wiring and eliminates the need for marshalling cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSE4302T02\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003e24 V DC Inductive Load CHARM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e4 V DC to 32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output Current\u003c\/td\u003e\n\u003ctd\u003e1.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e2.0 A (\u0026lt;100 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e≤1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Behavior\u003c\/td\u003e\n\u003ctd\u003eConfigurable: Momentary or Continuous Pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanically isolated, factory-tested to 1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Protection\u003c\/td\u003e\n\u003ctd\u003e4 A current limiting, thermal shutoff, automatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Protection\u003c\/td\u003e\n\u003ctd\u003eExternal fuse at power source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCHARM Power Requirement\u003c\/td\u003e\n\u003ctd\u003e22 mA max @ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e0.46 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eField-mountable, eliminates marshalling cabinets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eIdeal for chemical, power generation, and oil \u0026amp; gas industries where space-saving, field-mounted I\/O and reliable inductive load control are critical. The module simplifies wiring, reduces contact points, and enhances system reliability.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be used without a marshalling cabinet?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSE4302T02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for direct field installation, removing the need for a traditional marshalling cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the output protected against overloads?\u003c\/strong\u003e\u003cbr\u003eA: Built-in 4 A current limiting with thermal shutoff protects the module, while an external fuse is recommended at the power source.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What output behaviors are configurable?\u003c\/strong\u003e\u003cbr\u003eA: Outputs can be configured as momentary pulses or continuous pulses depending on the application requirements.\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":44072270725208,"sku":"SE4302T02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/EmersonSE4302T02-2.jpg?v=1778064619","url":"https:\/\/www.industriaxplc.com\/products\/emerson-se4302t02-deltav-do-24v-dc-isolated-charm-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}