{"product_id":"emerson-ovation-1c31107g01-digital-input-module-16-channel","title":"Emerson Ovation 1C31107G01 Digital Input Module | 16-Channel","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson Ovation 1C31107G01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance digital input module engineered for integration with the Ovation Distributed Control System (DCS). It provides reliable acquisition of discrete input signals from a wide range of field devices, supporting both process monitoring and automation control in industrial environments.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to 16 independent digital input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with 24 VAC, 24 VDC, 48 VDC signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperates in single-ended or differential configurations for flexible installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh noise immunity and robust signal detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for continuous industrial operation with minimal maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24\/48 VAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle-ended \/ Differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete (ON\/OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eEmerson Ovation DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel isolation supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcess monitoring in power plants, refineries, and water treatment facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with Ovation DCS for automated control loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring and diagnostics of field equipment such as sensors, switches, and relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module accept both AC and DC signals simultaneously?\u003c\/strong\u003e\u003cbr\u003eA: The module is configurable for either 24\/48 VAC or 24\/48 VDC inputs, but each channel must be wired consistently according to the selected mode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between single-ended and differential inputs?\u003c\/strong\u003e\u003cbr\u003eA: Single-ended inputs measure voltage relative to a common ground, while differential inputs measure the voltage difference between two terminals, providing higher noise immunity for long-distance signal transmission.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are similar modules available for higher channel counts?\u003c\/strong\u003e\u003cbr\u003eA: Emerson offers extended digital input modules in the Ovation series with up to 32 channels, suitable for larger systems requiring dense I\/O.\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":44100833771608,"sku":"1C31107G01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/1C31107G01-3.jpg?v=1778728432","url":"https:\/\/www.industriaxplc.com\/products\/emerson-ovation-1c31107g01-digital-input-module-16-channel","provider":"IndustriaX Limited","version":"1.0","type":"link"}