{"product_id":"emerson-kl3101x1-ba1-deltav-s-series-8-channel-dry-contact-input-module","title":"Emerson KL3101X1-BA1 DeltaV S-series 8-Channel Dry Contact Input Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL3101X1-BA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom Emerson is an 8-channel discrete input card designed for DeltaV S-series systems. It provides robust monitoring of field devices such as limit switches, pushbuttons, and relay contacts by converting physical contact closures into digital signals for the controller. Engineered for hazardous and standard industrial environments, it delivers reliable performance with minimal maintenance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDiscrete Signal Detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitors the open or closed state of 24V DC field circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides internal sensing voltage for dry contact inputs, eliminating the need for external power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNoise Filtering and Debouncing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable digital filtering ensures accurate readings without false triggering\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintains signal integrity in electrically noisy environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Response\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOptimized for low-latency input detection, essential for safety interlocks and high-speed automation sequences\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCertified for hazardous areas: ATEX, IECEx, FM, CSA, and CL1 DIV2 standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for energy-limited applications to meet safety integrity levels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistant to shock, vibration, and airborne contaminants per ISA-S71.04 Class G3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eS-series Reliability Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHot-swappable for replacement without system downtime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic identification by DeltaV controller upon insertion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous self-diagnostics to monitor internal health and functionality\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eFeature\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eKL3101X1-BA1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e8 Discrete Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e24V DC, Dry Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eON Detection Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u0026gt; 2.5 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOFF Detection Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u0026lt; 1.0 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eGalvanic isolation between field and controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eCHARM Bus: +6.3 VDC @ 0 mA; Field Circuit: +24 VDC @ 60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eShock \u0026amp; Vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e10 g half-sine, 11 ms; 1 mm p-p 2–13.2 Hz, 0.7 g 13.2–150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e5–95% Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eTerminal Block Key\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eDeltaV S-series horizontal I\/O carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eMaintenance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eNo user-serviceable parts; calibration not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis module is ideal for monitoring discrete field signals in chemical, oil \u0026amp; gas, power generation, and manufacturing plants. It supports sequence-of-events (SOE) recording when paired with compatible DeltaV controllers.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this card be installed while the system is powered?\u003c\/strong\u003e\u003cbr\u003eA: No, it must be inserted or removed only when system power is off to ensure safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the card require calibration?\u003c\/strong\u003e\u003cbr\u003eA: No calibration is necessary; the module is factory configured and maintenance-free.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of switches are supported?\u003c\/strong\u003e\u003cbr\u003eA: Designed for dry contact switches; internal 24V DC sensing voltage powers the field device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it compatible with older M-series hardware?\u003c\/strong\u003e\u003cbr\u003eA: No, this module is optimized for S-series carriers only.\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":44053229994072,"sku":"KL3101X1-BA1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/EmersonKL3101X1-BA1-3.jpg?v=1777510628","url":"https:\/\/www.industriaxplc.com\/products\/emerson-kl3101x1-ba1-deltav-s-series-8-channel-dry-contact-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}