{"product_id":"emerson-kj4006x1-bg1-deltav-s-series-16-channel-analog-input-block","title":"Emerson KJ4006X1-BG1 | DeltaV S-Series 16-Channel Analog Input Block","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ4006X1-BG1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 16-channel analog input terminal block engineered for the DeltaV™ S-Series Distributed Control System. It provides a robust interface between field-level analog sensors and S-Series I\/O modules, supporting both electronic marshalling and standard I\/O configurations. Built to meet stringent environmental and hazardous area standards, this terminal block ensures secure and reliable signal acquisition in modern industrial facilities.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Analog Connectivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports 16 analog input channels in a single footprint for efficient cabinet space utilization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with 2-wire, 3-wire, and 4-wire transmitters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for 4–20 mA signals from pressure, flow, and temperature sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Certification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eATEX, IECEx, and FM approved for Zone 2\/Class I, Div 2 applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned to minimize risk of sparks or shorts in environments with flammable gases or vapors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Environmental Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWithstands ISA-S71.04 Class G3 airborne contaminants for corrosion resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperational temperature range of -40°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShock rated at 10g half-sine wave, vibration compliant with 1mm peak-to-peak (2–13.2 Hz) and 0.7g (13.2–150 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety and Integrity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRotary keying ensures correct pairing with compatible I\/O cards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField power rated at 30 VDC and 100 mA per channel for reliable sensor operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielded wiring connections minimize electromagnetic interference (EMI) for accurate analog readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eKJ4006X1-BG1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDeltaV S-Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 VDC @ 100 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–95% Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area Certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATEX II 3G Ex ec IIC Gc, IECEx FMG 19.0019U, FM, Zone 2\/Div 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10g, 11 ms half-sine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1mm peak-to-peak (2–13.2 Hz), 0.7g (13.2–150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirborne Contaminant Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDeltaV S-Series I\/O Carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ4006X1-BG1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis suited for analog signal acquisition in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eChemical and oil \u0026amp; gas plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMarine and offshore facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous and harsh industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this terminal block be used with 4-wire transmitters?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports 2-wire, 3-wire, and 4-wire analog transmitters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the field power rating per channel?\u003c\/strong\u003e\u003cbr\u003eA: Each channel is rated for 30 VDC at 100 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does rotary keying enhance safety?\u003c\/strong\u003e\u003cbr\u003eA: Rotary keying ensures only compatible S-Series I\/O cards can be connected, preventing wiring errors and signal damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the block resistant to corrosion?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it meets ISA-S71.04 Class G3 standards for airborne contaminant protection.\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":44048614850648,"sku":"KJ4006X1-BG1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/EmersonKJ4006X1-BG1-3.jpg?v=1777427406","url":"https:\/\/www.industriaxplc.com\/products\/emerson-kj4006x1-bg1-deltav-s-series-16-channel-analog-input-block","provider":"IndustriaX Limited","version":"1.0","type":"link"}