{"product_id":"emerson-kj4001x1-ba3-12p0547x092-high-side-8-channel-rtu","title":"Emerson KJ4001X1-BA3 | 12P0547X092 | High-Side 8-Channel RTU","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson KJ4001X1-BA3 (12P0547X092)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an 8-channel, 24 VDC high-side remote termination unit (RTU) engineered for seamless integration with Emerson’s DeltaV™ Distributed Control System. It provides a secure interface between digital output modules and field devices, ensuring reliable signal transmission and protection in complex industrial environments.\u003c\/p\u003e\n\u003cp\u003eDesigned for robust industrial use, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ4001X1-BA3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincorporates individual channel fusing, integrated diagnostic LEDs, and high-side switching for enhanced operational safety. Its compact footprint and modular design allow easy installation on DeltaV M-series and S-series carriers.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Channel Protection\u003c\/strong\u003e\u003cbr\u003eEach of the 8 channels has dedicated fusing, isolating faults to the affected output and preventing disruption to the remaining circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Side Switching Architecture\u003c\/strong\u003e\u003cbr\u003eControls the positive power supply line to field devices, reducing the risk of accidental energization and improving safety in grounded fault conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Diagnostics\u003c\/strong\u003e\u003cbr\u003eEquipped with channel status indicators and blown-fuse LEDs, enabling quick identification of failures without specialized test equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Industrial Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -40°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eG3 Conformal Coating for resistance against humidity, salt air, and corrosive gases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration Resistance: 1 mm peak-to-peak (5–16 Hz) and 0.5 G (16–150 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShock Resistance: 10 G, 11 ms sinewave\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Installation\u003c\/strong\u003e\u003cbr\u003ePre-wired mass-termination cable connects to DeltaV I\/O modules, minimizing wiring errors and reducing commissioning time.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eFeature\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eKJ4001X1-BA3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e12P0547X092\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e8 independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eMaximum Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e8 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eMaximum Operating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eSwitching Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eHigh-Side (Source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eFusing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eIndividual per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eChannel status LEDs, blown-fuse LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eDeltaV M-series or S-series carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eConformal Coating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eG3 (ISA-S71.04-1985)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e1 mm (5–16 Hz), 0.5 G (16–150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e10 G, 11 ms sinewave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e13.0 cm × 1.9 cm × 19.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eHazardous Area Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eATEX, UL, FM Class 1 Div 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eDiscontinued by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIdeal for controlling solenoids, relays, and other field actuators in process automation, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ4001X1-BA3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports safe and isolated switching in chemical, oil and gas, and manufacturing environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the KJ4001X1-BA3 compatible with older DeltaV modules?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it maintains backward compatibility with most DeltaV systems, provided the field device current does not exceed fuse ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the unit handle continuous 8 A per channel?\u003c\/strong\u003e\u003cbr\u003eA: Yes, but it should not exceed the rated maximum operating voltage of 30 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens if one channel shorts?\u003c\/strong\u003e\u003cbr\u003eA: The affected channel’s fuse will blow, isolating the fault while the remaining channels continue operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this unit be used in hazardous areas?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is rated for ATEX, UL, and FM Class 1 Div 2 environments.\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":44044873826392,"sku":"KJ4001X1-BA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/EmersonKJ4001X1-BA3-3.jpg?v=1777357017","url":"https:\/\/www.industriaxplc.com\/products\/emerson-kj4001x1-ba3-12p0547x092-high-side-8-channel-rtu","provider":"IndustriaX Limited","version":"1.0","type":"link"}