{"product_id":"emerson-kj1501x1-bc1-dual-dc-dc-power-controller-deltav-module","title":"Emerson KJ1501X1-BC1 Dual DC\/DC Power Controller DeltaV Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ1501X1-BC1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDual DC\/DC Power Controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the Emerson DeltaV™ S-series Distributed Control System (DCS). It regulates and distributes power to I\/O and controller modules, supporting both 12 VDC and 24 VDC input systems. Engineered for industrial environments, it delivers stable outputs while maintaining system redundancy to prevent downtime.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Power Input \u0026amp; Redundancy\u003c\/strong\u003e: Handles two independent power feeds for fault-tolerant operation. Failure of one supply does not disrupt system functionality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy-Limited Alarm Circuits\u003c\/strong\u003e: Supports Uo = 30 VDC, Io = 135 mA, ensuring safe operation in hazardous areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swappable Design\u003c\/strong\u003e: Can be installed or removed following proper safety protocols without affecting other modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Resilience\u003c\/strong\u003e: Designed to endure shock (10 g, ½ sine, 11 ms), vibration, airborne contaminants (ISA-S71.04 Class G3), and wide temperature ranges (0–60°C operational).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecise Power Conversion\u003c\/strong\u003e: Provides regulated outputs: +12 VDC at 13 A (12 V input), +12 VDC at 4.5 A (24 V input), +5 VDC at 2 A, 3.3 VDC at 2 A, with total output power up to 10 W at 60°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Compliance\u003c\/strong\u003e: Certified II 3 G, Nemko No. 02ATEX431U, EEx nC IIC T4, with inductance Lo = 3.55 μH.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e12 VDC (11.4–12.6 VDC), 24 VDC (22.8–25.2 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage \u0026amp; Current\u003c\/td\u003e\n\u003ctd\u003e+12 VDC 13 A (12 V input), +12 VDC 4.5 A (24 V input), +5 VDC 2 A, 3.3 VDC 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Output Power\u003c\/td\u003e\n\u003ctd\u003e10 W at 60°C (combined 5 VDC + 3.3 VDC outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Circuit\u003c\/td\u003e\n\u003ctd\u003eUo = 30 VDC, Io = 135 mA, Li = 0, Ci = 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Rating\u003c\/td\u003e\n\u003ctd\u003eII 3 G, Nemko No. 02ATEX431U, EEx nC IIC T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInductance\u003c\/td\u003e\n\u003ctd\u003eLo = 3.55 µH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e0–60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e10 g, ½ sine, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak (5–16 Hz), 0.5 g (16–150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5–95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirborne Contaminants\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDeltaV S-series Power\/Controller Carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Control Systems\u003c\/strong\u003e: Maintains reliable power for I\/O modules in refineries, chemical plants, and utilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Areas\u003c\/strong\u003e: Meets stringent ATEX and IECEx certifications for safe deployment in flammable atmospheres.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Availability Facilities\u003c\/strong\u003e: Supports redundant input configurations for zero-downtime operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation \u0026amp; Maintenance Notes\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMust remove field power before module insertion or removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIn 12 VDC passthrough mode, ensure input source does not exceed 12.6 VDC or 16 A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContains no user-serviceable components. Disassembly is prohibited.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration is not required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module operate in hazardous environments?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is certified for ATEX Zone 2 (II 3 G) and Class 1 Div 2 conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens if one input power source fails?\u003c\/strong\u003e\u003cbr\u003eA: The module continues to supply power using the secondary input without interruption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it compatible with other DeltaV power modules?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it integrates with S-series carriers and supports dual DC\/DC input redundancy.\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":44048494198872,"sku":"KJ1501X1-BC1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/EmersonKJ1501X1-BC1-2.jpg?v=1777424497","url":"https:\/\/www.industriaxplc.com\/products\/emerson-kj1501x1-bc1-dual-dc-dc-power-controller-deltav-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}