{"product_id":"emerson-kc3010x1-ba1-deltav-s-series-analog-input-plus-module","title":"Emerson KC3010X1-BA1 DeltaV S-series Analog Input Plus Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKC3010X1-BA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Analog Input (AI) Plus module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeltaV S-series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control System (DCS). Engineered for complex process environments, this 16-channel module integrates HART communication while maintaining robust operation in hazardous areas. It supports both 2-wire and 4-wire transmitters and ensures precise signal acquisition for critical process monitoring.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16 Analog Channels\u003c\/strong\u003e: Consolidates multiple process signals into a single module to reduce cabinet footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHART Pass-Through\u003c\/strong\u003e: Enables communication with HART-enabled field devices for diagnostics and configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Reliability\u003c\/strong\u003e: Supports online maintainability and hot-swappable operation without disrupting other I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Protection\u003c\/strong\u003e: Includes G3 conformal coating for corrosive environments, open circuit detection, and high-resolution A\/D conversion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Certification\u003c\/strong\u003e: ATEX Zone 2, IECEx, and Class I Div 2 compliant, ensuring safe installation in explosive atmospheres.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Plus, 16-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC, HART compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003ev5, v6, v7 pass-through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocalBus Power\u003c\/td\u003e\n\u003ctd\u003e12 VDC, 150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Output\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 30 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e10 g, half-sine, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5–95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirborne Contaminants\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Keying\u003c\/td\u003e\n\u003ctd\u003eRotary key system for I\/O card compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eIdeal for chemical, petrochemical, and manufacturing plants where high-density analog signal acquisition and HART integration are required. It is particularly suited for continuous processes where high availability and predictive maintenance are critical.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be replaced while the system is powered?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the KC3010X1-BA1 supports hot-swappable installation on the S-series carrier.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it require calibration?\u003c\/strong\u003e\u003cbr\u003eA: No calibration is necessary. The module is factory calibrated and ready for use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which terminal block should I use?\u003c\/strong\u003e\u003cbr\u003eA: Use a compatible high-density 10-pin or 16-pin terminal block (e.g., KJ3221X1-EA1) to fully utilize all channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it suitable for hazardous locations?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is certified for ATEX Zone 2, IECEx, and Class I Div 2 hazardous areas.\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":44045498155096,"sku":"KC3010X1-BA1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/EmersonKC3010X1-BA1.jpg?v=1777363872","url":"https:\/\/www.industriaxplc.com\/products\/emerson-kc3010x1-ba1-deltav-s-series-analog-input-plus-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}