{"product_id":"emerson-deltav-kl3106x1-ls1-safety-discrete-input-charm","title":"Emerson DeltaV KL3106X1-LS1 Safety Discrete Input CHARM","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson DeltaV KL3106X1-LS1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a single-channel Discrete Input CHARM designed for the DeltaV LS (Logic Solver) series. It provides reliable monitoring of 24V DC dry contact signals from safety-critical field devices while maintaining SIL 3-level safety and intrinsic isolation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL 3 Safety Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompliant with IEC 61508\/61511, ensures fast and deterministic reporting of discrete input states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectronic Marshalling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFlexible I\/O mapping, supports late binding to simplify wiring and cabinet design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDetects open\/short circuits, LED status for quick diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Robustness:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eISA-S71.04 Class G3 coating, operating range -40°C to +70°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swappable:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan be replaced without powering down adjacent modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eFeature\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eInput Type\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e24V DC Dry Contact (Low-Side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eChannel Count\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eIsolation\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eGalvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eLED Indicators\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eGreen = Normal, Red = Fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eCHARM Bus Power\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e+6.3 VDC at 0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eField Circuit Power\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e+24 VDC at 23 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eEnergy-Limited Output\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e24V DC, max 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eShock\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e10g, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eVibration\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e1 mm (5–16 Hz), 0.5g (16–150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eEnvironmental\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eISA-S71.04 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eDimensions\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e5.1 × 1.9 × 3.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eWeight\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.03 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSafety switches, level sensors, and emergency stop monitoring in SIL 3 loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous area installations in chemical, petrochemical, and oil \u0026amp; gas plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan it be replaced under power?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it is hot-swappable within LS-series safety cabinets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIs calibration required?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, it is factory-calibrated and maintenance-free.\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":44053796651096,"sku":"KL3106X1-LS1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/EmersonKL3106X1-LS1-3.jpg?v=1777520062","url":"https:\/\/www.industriaxplc.com\/products\/emerson-deltav-kl3106x1-ls1-safety-discrete-input-charm","provider":"IndustriaX Limited","version":"1.0","type":"link"}