{"product_id":"emerson-deltav-kl3105x1-ba1-i-s-thermocouple-module-charm","title":"Emerson DeltaV KL3105X1-BA1 I.S. Thermocouple Module | CHARM","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson DeltaV KL3105X1-BA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision Intrinsically Safe (I.S.) CHARM designed for DeltaV Electronic Marshalling systems. This module supports direct connection to temperature sensors and low-voltage signals in hazardous areas without requiring external I.S. barriers, simplifying installation while ensuring safety and measurement accuracy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eIntrinsically Safe Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated galvanic isolation meets\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIECEx ia\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand ATEX requirements for Zone 0 \/ Class I, Div 1 environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEliminates external barrier cabinets, reducing wiring complexity and panel footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports installation in Zone 2\/Class I Div 2 environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePrecision Measurement\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with Thermocouple types B, E, J, K, N, R, S, T.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccepts millivolt inputs from -100 mV to +100 mV.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInternal cold junction compensation ensures accurate temperature readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-resolution ADC ensures stable and precise data acquisition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostics and Reliability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDetects sensor faults, open circuits, and wiring issues.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLED indicators: Green (normal), Blinking Red (field fault), Solid Red (module fault).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHot-swappable under appropriate hazardous area guidelines without interrupting other channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eFeature\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eInput Type\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eThermocouple \/ Millivolt (-100 mV to +100 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eI\/O Type\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eIntrinsically Safe Analog Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eBus Power\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e+6.3 VDC at 0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eField Circuit Power\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e+24 VDC at 23 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eShock\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e10g, 11 ms, half-sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eVibration\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e1 mm peak-to-peak (2–13.2 Hz); 0.7g (13.2–150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eEnvironmental\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eISA-S71.04 Class G3 Airborne Contaminants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eTerminal Block Keying\u003c\/td\u003e\n\u003ctd align=\"left\"\u003ePosition C5 (prevents incorrect insertion)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eField-mounted junction boxes in hazardous zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature monitoring in chemical, petrochemical, and oil \u0026amp; gas plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystems requiring flexible, late-binding I\/O configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module be removed while the system is powered?\u003c\/strong\u003e\u003cbr\u003eA: No, the module must be inserted or removed only with system power off.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is calibration required for operation?\u003c\/strong\u003e\u003cbr\u003eA: No calibration is needed; the module is factory-calibrated.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module support external I.S. barriers?\u003c\/strong\u003e\u003cbr\u003eA: No external barriers are required; the CHARM provides built-in isolation and energy-limiting circuitry.\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":44053750480984,"sku":"KL3105X1-BA1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/EmersonKL3105X1-BA1-3.jpg?v=1777519181","url":"https:\/\/www.industriaxplc.com\/products\/emerson-deltav-kl3105x1-ba1-i-s-thermocouple-module-charm","provider":"IndustriaX Limited","version":"1.0","type":"link"}