{"product_id":"emerson-deltav-kl3021x1-ba1-analog-input-hart-module-s-series","title":"Emerson DeltaV KL3021X1-BA1 Analog Input HART Module S-Series","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson DeltaV KL3021X1-BA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an advanced analog input module designed for high-performance process control. Part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS-Series (Series 2)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O family, this 8-channel 4-20 mA card integrates HART communication to provide both analog measurements and access to digital diagnostics from smart field instruments. Its compact design allows seamless installation on S-Series horizontal carriers while delivering reliable, precise process data.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eHART Communication Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProvides access to device diagnostics, secondary variables, and configuration parameters from HART-enabled transmitters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports multi-variable readings from a single field device, enhancing system visibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePrecision and Stability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-resolution ADC ensures accurate, stable measurements for critical control loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFast update rates reduce lag and maintain timely process feedback\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety and Reliability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIndividual channel isolation prevents ground loops and protects against electrical surges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports redundant installations with terminal blocks and carriers for high-availability applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCertified for hazardous locations: Zone 2 \/ Class I, Division 2 environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMaintenance and Flexibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHot-swappable design allows replacement without system shutdown\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic system recognition simplifies commissioning and module swaps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSelf-diagnostic monitoring reduces field troubleshooting and maintenance efforts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003cth align=\"left\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eChannels\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e8 Analog Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eSignal Type\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e4-20 mA DC with HART protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eHART Version\u003c\/td\u003e\n\u003ctd align=\"left\"\u003ev5, v6, v7 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eIsolation\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eChannel-to-system galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eNominal Signal Range\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e3.8 mA to 20.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-40°C to +70°C (-40°F to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eShock Resistance\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e10g, 11ms half-sine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eVibration\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e1mm peak-to-peak 2–13.2Hz; 0.7g 13.2–150Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eContaminant Rating\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eISA-S71.04 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eHumidity\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e5–95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eCHARM bus +6.3 VDC @ 32 mA; Field circuit +24 VDC @ 25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eApprovals\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eATEX, IECEx, FM, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIdeal for integrating HART-enabled pressure, temperature, and flow transmitters into DeltaV control systems. Supports both continuous process monitoring and predictive maintenance strategies in hazardous and industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the KL3021X1-BA1 be installed while the system is powered?\u003c\/strong\u003e\u003cbr\u003eA: Only in non-hazardous areas. Hot-swapping in hazardous zones requires following DeltaV safety procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it require calibration after installation?\u003c\/strong\u003e\u003cbr\u003eA: No, the module is factory-calibrated and does not require field calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it detect wiring faults?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it provides open- and short-circuit detection for all connected field devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it compatible with redundant setups?\u003c\/strong\u003e\u003cbr\u003eA: Yes, when paired with a redundant terminal block and carrier, it supports full process redundancy.\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":44048837312600,"sku":"KL3021X1-BA1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/EmersonKL3021X1-BA1-3.jpg?v=1777431743","url":"https:\/\/www.industriaxplc.com\/products\/emerson-deltav-kl3021x1-ba1-analog-input-hart-module-s-series","provider":"IndustriaX Limited","version":"1.0","type":"link"}