{"product_id":"emerson-a6824r-modbus-rack-interface-module-imr6500-series","title":"Emerson A6824R ModBus Rack Interface Module IMR6500 Series","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6824R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom Emerson is a high-performance ModBus and rack interface module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIMR6500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries machinery protection systems. Its 4TE wide, 1-slot plug-in format optimizes cabinet space, reducing the footprint by half compared to traditional 6U cards. This module supports optional redundancy, hot-swappable installation, and comprehensive self-monitoring to ensure reliable system performance in critical applications.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Saving Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4TE \/ 1-slot format minimizes cabinet space requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Option:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports redundant configuration for fail-safe operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swappable:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan be installed or replaced without powering down the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAPI 670 Compliant:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeets international standards for machinery protection systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePassword-protected settings prevent unauthorized changes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSelf-Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eContinuous checks on hardware status, input power, and module temperature.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Rack Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSingle module can serve multiple 19” racks, enabling flexible deployment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEasy Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated handle allows quick removal and identification of the module and sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eCommunication \u0026amp; Data\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModBus RTU (Serial):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e19.2 kBaud, 8 data bits, even parity, 1 stop bit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDefault IP Address:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e192.168.255.1, Subnet Mask: 255.255.255.0.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModBus Ethernet:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRJ45 socket, 10Base-T.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGreen LED shows power supply health.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eA6824R\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModBus Rack Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIMR6500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4TE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHot-Swap Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModBus RTU Serial \u0026amp; ModBus Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Baud Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kBaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Bits \/ Parity \/ Stop Bits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 \/ Even \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault Network Address\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e192.168.255.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubnet Mask\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255.255.255.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45, 10Base-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for Power Status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSelf-Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware, Power Input, Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-Swappable \/ 1-Slot Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAPI 670 Machinery Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant data communication in machinery protection systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with CSI 6500 and IMR6500 racks for vibration and speed monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptimized for industrial environments where rack space and hot-swap flexibility are critical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports secure multi-rack deployment in plant-wide monitoring networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be used in IMR6000 series racks?\u003c\/strong\u003e\u003cbr\u003eA: No, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6824R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed specifically for the IMR6500 series. A separate 6TE, non-redundant version exists for IMR6000.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module require powering down the rack for installation?\u003c\/strong\u003e\u003cbr\u003eA: No, it is fully hot-swappable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is redundancy configured?\u003c\/strong\u003e\u003cbr\u003eA: Redundancy can be enabled through the module configuration menu, providing automatic failover between primary and backup channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of network interfaces are supported?\u003c\/strong\u003e\u003cbr\u003eA: ModBus RTU over serial and ModBus Ethernet via RJ45 10Base-T.\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":44088213471320,"sku":"A6824R","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/A6824R-3.jpg?v=1778312282","url":"https:\/\/www.industriaxplc.com\/products\/emerson-a6824r-modbus-rack-interface-module-imr6500-series","provider":"IndustriaX Limited","version":"1.0","type":"link"}