{"product_id":"double-format-pl7-processor-tsxp57303am-schneider-electric","title":"Double-Format PL7 Processor TSXP57303AM Schneider Electric","description":"\u003ch2\u003eSchneider Electric TSXP57303AM Double-Format PL7 Processor\u003c\/h2\u003e\n\u003cp\u003eConfigured for deterministic logic execution in the Modicon Premium Automation platform, the \u003cstrong\u003eSchneider Electric TSXP57303AM\u003c\/strong\u003e, also referenced as the \u003cstrong\u003eTSXP57\u003c\/strong\u003e double-format PL7 processor, provides direct physical backplane communication and discrete\/analog I\/O processing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXP57303AM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e95 mm x 180 mm x 260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1000 mA @ 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e1024 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e128 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Control Channels\u003c\/td\u003e\n\u003ctd\u003e15 to 45 simple loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Link\u003c\/td\u003e\n\u003ctd\u003eNon-isolated, 19.2\/115 kbit\/s, female mini DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Overhead\u003c\/td\u003e\n\u003ctd\u003e0.29 ms fast task, 1.15 ms master task\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe TSXP57303AM utilizes the Modicon Premium backplane bus architecture for deterministic data exchange between processor and I\/O modules. Firmware revisions must match the installed PL7 software version; mismatched flash loads will prevent task scheduling. The processor supports up to 8 AS-Interface bus modules and 3 network modules concurrently, with reduced fieldbus capacity when CANopen is active.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the TSXP57303AM be hot-swapped while the rack remains powered?\u003c\/p\u003e\n\u003cp\u003eA: No. The module must be inserted or removed only after removing 5 V DC backplane power to avoid corruption of volatile memory and I\/O mapping tables.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum analog input loading per rack with this processor?\u003c\/p\u003e\n\u003cp\u003eA: The processor supports up to 128 analog I\/O points distributed across all connected racks, regardless of slot population density.\u003c\/p\u003e\n\u003cp\u003eQ: Does firmware downgrade require reconfiguration of application logic?\u003c\/p\u003e\n\u003cp\u003eA: Downgrading may cause incompatibility with certain process control function blocks; verify PL7 software compatibility before flashing older firmware.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the TSXP57303AM into a grounded, metallic DIN rail assembly within an IP20-rated enclosure. Maintain clearance for heat dissipation—minimum 50 mm above and below the module. Use shielded twisted-pair cabling for serial links and connect shield drains directly to the rack ground bar. Avoid routing signal wiring parallel to high-current AC feeders to minimize inductive coupling. Verify backplane seating by checking RUN LED status after power-up.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44273414668376,"sku":"TSXP57303AM","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TSXP57303AM.jpg?v=1782293071","url":"https:\/\/www.industriaxplc.com\/products\/double-format-pl7-processor-tsxp57303am-schneider-electric","provider":"IndustriaX Limited","version":"1.0","type":"link"}