{"product_id":"do840-3bse020838r1-abb-s800-i-o-digital-output-modules","title":"DO840 3BSE020838R1 ABB S800 I\/O Digital Output Modules","description":"\u003ch2\u003eABB DO830 3BSE020838R1 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB DO830 3BSE020838R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDO830\u003c\/strong\u003e Digital Output Module, provides direct electrical execution of current sourcing output signals within the ABB S800 I\/O system. It contains 16 digital output channels with 24 VDC signal operation, current limitation, over temperature protection, and groupwise isolation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO830 3BSE020838R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eWidth 45 mm, Depth 102 mm, Height 119 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTyp. 4.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e24 VDC (19.2 to 32 VDC), 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 digital output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sourcing, current limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eMaximum 0.5 A per channel continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Integrity\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGroupwise isolated from ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Protection\u003c\/td\u003e\n\u003ctd\u003eShort circuit proof current limited output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Cable Length\u003c\/td\u003e\n\u003ctd\u003eMaximum 600 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Current Consumption +5 V\u003c\/td\u003e\n\u003ctd\u003e130 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Current Consumption +24 V\u003c\/td\u003e\n\u003ctd\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal +24 V Current Consumption\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible MTU\u003c\/td\u003e\n\u003ctd\u003eTU810, TU812, TU814, TU830, TU833, TU842, TU843, TU852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Code\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4, EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Approval\u003c\/td\u003e\n\u003ctd\u003eC1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certification\u003c\/td\u003e\n\u003ctd\u003eDNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2, IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04 G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEU RoHS, UAE RoHS, CN RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Compliance\u003c\/td\u003e\n\u003ctd\u003eDirective 2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O Backplane and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe DO830 operates as an ABB S800 I\/O digital output component with direct ModuleBus communication to the control system. The module integrates 16 output channels in a compact S800 mechanics design and supports redundant configurations through compatible termination units.\u003c\/p\u003e\n\u003cp\u003eEach output channel uses a high side driver with current limitation, over temperature protection, EMC protection components, inductive load suppression, status indication LED, and optical isolation. Therefore, the module maintains electrical separation between field circuits and internal electronics.\u003c\/p\u003e\n\u003cp\u003eThe output architecture supports I\/O density scaling within ABB automation systems while maintaining channel-level diagnostics. In addition, the module provides process voltage supervision through two groups, with each group containing eight output channels and one supervision input.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DO830 support HART or Sequence of Events (SOE) functions?\u003cbr\u003eA: No. The DO830 is a digital output module without HART communication or SOE event recording capability.\u003c\/p\u003e\n\u003cp\u003eQ: How are the output channels protected against field faults?\u003cbr\u003eA: Each output channel includes current limitation and over temperature protection. The output design provides short circuit proof operation.\u003c\/p\u003e\n\u003cp\u003eQ: Which MTUs are compatible with the DO830 module?\u003cbr\u003eA: The DO830 supports TU810, TU812, TU814, TU830, TU833, TU842, TU843, and TU852 termination units.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the DO830 module according to ABB S800 I\/O mechanical and electrical installation requirements.\u003c\/p\u003e\n\u003cp\u003eConnect field wiring through the specified compatible MTU and verify correct keying before module insertion. Maintain proper separation between signal wiring and high voltage power cables to reduce EMC interference.\u003c\/p\u003e\n\u003cp\u003eVerify external 24 VDC field supply polarity before energizing the outputs. The protective earth and cabinet grounding system must follow site electrical standards.\u003c\/p\u003e\n\u003cp\u003eUse shielded cables where required by the installation environment. Connect cable shields according to the control cabinet grounding design to minimize electrical noise coupling.\u003c\/p\u003e\n\u003cp\u003eCheck front LED indicators after startup. Confirm module status, warning indication, and individual channel status before placing the output channels into operational service.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44650531586136,"sku":"DO840 3BSE020838R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DO840-3BSE020838R1-3_1200x1200_eebcf5fb-0aa7-4318-bf84-72400aa881d5.jpg?v=1787563139","url":"https:\/\/www.industriaxplc.com\/products\/do840-3bse020838r1-abb-s800-i-o-digital-output-modules","provider":"IndustriaX Limited","version":"1.0","type":"link"}