{"product_id":"digital-output-modules-schneider-electric-modicon-tsxdst2472","title":"Digital Output Modules | Schneider Electric Modicon TSXDST2472","description":"\u003ch2\u003eSchneider Electric TSXDST2472 Digital Output Modules\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete signal actuation in Modicon backplane I\/O architectures, the \u003cstrong\u003eSchneider Electric TSXDST2472\u003c\/strong\u003e (\u003cstrong\u003eTSXDST2472\u003c\/strong\u003e Output Module) provides direct electrical switching of field devices through 24 V DC digital output channels across rack-based PLC systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eNo explicit suffix segmentation or functional variant coding is defined for TSXDST2472 in the provided specification set. The designation is treated as a single fixed module identifier within the Modicon output module family.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric TSXDST2472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.25 lbs (0.57 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 degC to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete (Digital)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e24 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current per Point\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Output Current\u003c\/td\u003e\n\u003ctd\u003e8 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel to logic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eShort-circuit and overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the TSXDST2472 support hot-swap insertion under live backplane power?\u003cbr\u003eA: Hot-swap capability is not specified. Standard practice requires power isolation of the rack before module insertion or removal to prevent backplane disturbance.\u003c\/p\u003e\n\u003cp\u003eQ: What is the output switching behavior during PLC scan cycle jitter?\u003cbr\u003eA: Output state updates are synchronized to the backplane scan cycle. Any jitter is constrained by CPU scan timing and rack communication scheduling.\u003c\/p\u003e\n\u003cp\u003eQ: Can channels operate independently under partial overload conditions?\u003cbr\u003eA: Yes. Each channel includes individual short-circuit and overload protection, limiting fault impact to the affected output point only.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure DIN rail or rack mounting alignment is mechanically secured before applying backplane connection force. Verify 24 V DC field wiring polarity prior to energization. Maintain separation between output wiring harnesses and high-noise conductors to reduce induced coupling on fast-switching channels.\u003c\/p\u003e\n\u003cp\u003eShield grounding should be terminated at a single reference earth point to avoid circulating ground currents across the output cabinet. Do not exceed 0.5 A per channel or 8 A total module load. Allow sufficient ventilation spacing within the rack to maintain thermal stability within 0 degC to 60 degC operating limits.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44225557594200,"sku":"TSXDST2472","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TSXDST2472-3.jpg?v=1781251362","url":"https:\/\/www.industriaxplc.com\/products\/digital-output-modules-schneider-electric-modicon-tsxdst2472","provider":"IndustriaX Limited","version":"1.0","type":"link"}