{"product_id":"digital-output-module-adv569-p50-yokogawa-new-original-stock","title":"Digital Output Module ADV569-P50 Yokogawa | New \u0026 Original Stock","description":"\u003ch1\u003eYokogawa ADV569-P50 Digital Output Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for transistor-based digital output execution in CENTUM process control networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV569-P50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eADV569\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output Module) provides direct physical\/electrical execution. The module supports 64 isolated output channels with current sink transistor outputs, one-shot pulse generation, and time-proportioning output control for discrete field interfacing within Yokogawa DCS architectures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV569\u003c\/td\u003e\n\u003ctd\u003eBase digital output module platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P50\u003c\/td\u003e\n\u003ctd\u003eFactory-defined suffix variant for CENTUM-compatible hardware configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV569-P50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTransistor contact (current sink)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eCommon every 16 channels on negative side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Load Voltage\u003c\/td\u003e\n\u003ctd\u003e30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current (OFF)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e16 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Range\u003c\/td\u003e\n\u003ctd\u003e8 ms to 7200 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Resolution\u003c\/td\u003e\n\u003ctd\u003e8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Delay Accuracy\u003c\/td\u003e\n\u003ctd\u003eUp to 1 ms ON\/OFF delay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Load Type\u003c\/td\u003e\n\u003ctd\u003eResistive and inductive loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Requirement\u003c\/td\u003e\n\u003ctd\u003eExternal diode required for DC relay driving\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eDual redundancy supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e800 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel Isolation and Process Signal Segmentation\u003c\/h3\u003e\n\u003cp\u003eThe ADV569-P50 implements channel grouping isolation on the negative side for every 16 output channels. This segmentation structure reduces common return interference during simultaneous transistor switching operations inside distributed process control cabinets. The module is designed for discrete signal execution associated with process sequence timing, pulse-driven actuation, and time-proportioning output behavior within CENTUM systems.\u003c\/p\u003e\n\u003cp\u003eThe output circuitry supports both resistive and inductive field loads. When driving DC relay coils or inductive devices, external flyback diode protection is required to suppress reverse transient voltage across the transistor output stage.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ADV569-P50 support redundant operation within CENTUM systems?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module supports dual redundancy operation when installed within compatible Yokogawa system architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module directly drive inductive DC relay loads?\u003c\/strong\u003e\u003cbr\u003eA: Yes, but external diode suppression must be installed across relay coils to prevent reverse voltage transients during output de-energization.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What output timing functions are available on the module?\u003c\/strong\u003e\u003cbr\u003eA: The module supports one-shot pulse output from 8 ms to 7200 s and time-proportioning output control with up to 1 ms ON\/OFF delay capability.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eBefore installation, isolate cabinet control power and verify backplane compatibility with the designated CENTUM node configuration. Maintain separation between output wiring bundles and analog signal cabling to reduce switching noise propagation.\u003c\/p\u003e\n\u003cp\u003eFor inductive load wiring, install flyback suppression diodes directly at the field device terminals rather than at the marshalling cabinet whenever possible. Shield grounding should follow single-point cabinet grounding practices to avoid circulating return currents between channel groups.\u003c\/p\u003e\n\u003cp\u003eConfirm load current remains below 100 mA per channel during steady-state operation. Excessive inrush current from solenoids or relay assemblies should be evaluated before field energization.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44143041806424,"sku":"ADV569-P50","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ADV569-P50.jpg?v=1779757928","url":"https:\/\/www.industriaxplc.com\/products\/digital-output-module-adv569-p50-yokogawa-new-original-stock","provider":"IndustriaX Limited","version":"1.0","type":"link"}