{"product_id":"digital-input-module-yokogawa-f3xd32-3f","title":"Digital Input Module Yokogawa F3XD32-3F","description":"\u003ch2\u003eYokogawa F3XD32-3F Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed 24 V DC discrete signal acquisition in FA-M3 platform, the \u003cstrong\u003eYokogawa F3XD32-3F\u003c\/strong\u003e (\u003cstrong\u003eF3XD32-3F\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution for 32-point digital input sampling within Yokogawa FA-M3 controller backplane architecture.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe suffix structure of F3XD32-3F is not explicitly defined in publicly provided electrical breakdown documentation. The model is identified as part of the F3XD32 high-density digital input family, with \"-3F\" commonly used by the manufacturer to indicate a high-speed variant with enhanced filtering capability. No further official segmentation is assumed.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa F3XD32-3F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 140 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e5 V DC, approx. 110 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e32 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003eApprox. 4.1 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eOFF-\u0026gt;ON \u0026lt;= 0.1 ms, ON-\u0026gt;OFF \u0026lt;= 0.1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003e40-pin high-density connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and High-Speed Input Filtering Architecture\u003c\/h3\u003e\n\u003cp\u003eThe module implements photocoupler-based channel isolation between field input circuits and internal logic backplane. Input channels are arranged in grouped structures to reduce cross-channel interference under high-density switching conditions. Internal digital filtering parameters are software configurable, allowing suppression of contact bounce and high-frequency noise on 24 V DC signal lines. The architecture supports deterministic state detection suitable for high-speed discrete signal acquisition in FA-M3 I\/O scanning cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module be hot-swapped during FA-M3 system operation?\u003c\/strong\u003e\u003cbr\u003eA: Hot-swap capability depends on the base unit configuration. Electrical removal during backplane energization may result in signal interruption and should follow system power-down procedures unless explicitly supported by the rack configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does each input channel share a common return path?\u003c\/strong\u003e\u003cbr\u003eA: Input channels are grouped with shared common terminals per isolation group. Channel-to-channel isolation is implemented via photocouplers, not full per-channel galvanic isolation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the effect of input filter adjustment on response time?\u003c\/strong\u003e\u003cbr\u003eA: Increasing the digital filter time introduces additional delay beyond the default \u0026lt;= 0.1 ms response window, reducing sensitivity to short-duration pulses.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eBackplane insertion must be performed with system power removed unless the FA-M3 base unit explicitly supports live insertion. Ensure correct alignment of the 40-pin connector to prevent pin deformation. Field wiring should be routed through shielded cable assemblies to minimize electromagnetic coupling on 24 V DC input lines. Shield grounding should be terminated at a single-point earth reference to avoid ground loop currents. Maintain separation between input signal cables and high-voltage or switching power lines to reduce induced noise on high-speed channels.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44176218947672,"sku":"F3XD32-3F","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/F3XD32-3F.jpg?v=1780457266","url":"https:\/\/www.industriaxplc.com\/products\/digital-input-module-yokogawa-f3xd32-3f","provider":"IndustriaX Limited","version":"1.0","type":"link"}