{"product_id":"digital-input-module-adv151-p63-d5a00-yokogawa","title":"Digital Input Module ADV151-P63\/D5A00 | Yokogawa","description":"\u003ch1\u003eYokogawa ADV151-P63\/D5A00 Digital Input Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for 32-channel digital signal acquisition in CENTUM and compatible Yokogawa DCS architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV151-P63\/D5A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eADV151\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input Module) provides direct physical\/electrical execution for 24 VDC sink\/source status input processing through pressure clamp or dedicated cable termination interfaces.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eCode Segment\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV151\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP\u003c\/td\u003e\n\u003ctd\u003eWith pushbutton input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eWith status display; no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option and -20 to 70 degC temperature option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD5A00\u003c\/td\u003e\n\u003ctd\u003eWith KS Cable Interface Adapter for 32-channel digital signals (ATD5A-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-P63\/D5A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (sink\/source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003e5.0 VDC or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA +\/-20 % per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Allowable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e30.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e8 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kVAC for 1 minute between input signal and system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Isolation\u003c\/td\u003e\n\u003ctd\u003e500 VAC for 1 minute between commons every 16-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal, AKB331 cable, MIL connector cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel Isolation and DCS Signal Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe module supports 24 VDC discrete input acquisition with grouped common isolation across each 16-channel segment. Input transition recognition is internally conditioned for status signal handling with response timing maintained within 8 ms. The D5A00 option integrates the KS cable interface adapter structure for direct termination of 32-channel digital field signals into Yokogawa DCS marshalling assemblies.\u003c\/p\u003e\n\u003cp\u003eThe ADV151 architecture supports sink\/source input logic compatibility, allowing mixed field device interfacing under common industrial discrete I\/O standards. The G3 environmental specification extends tolerance against corrosive atmospheres typically associated with control cabinet installations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ADV151-P63\/D5A00 support both sink and source input devices?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module is specified for 24 VDC sink\/source discrete input operation within the rated voltage range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What field termination methods are supported by this module?\u003c\/strong\u003e\u003cbr\u003eA: The module supports pressure clamp terminals, Yokogawa AKB331 dedicated cables, and MIL connector cable interfaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is channel-to-channel isolation individually implemented on all 32 inputs?\u003c\/strong\u003e\u003cbr\u003eA: No. Common isolation is implemented per 16-channel group with 500 VAC withstand voltage between commons.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module inside a grounded control cabinet with segregated routing between discrete input wiring and high-energy AC power conductors. Maintain shield grounding at a single designated cabinet grounding point to minimize induced switching noise.\u003c\/p\u003e\n\u003cp\u003eVerify field input voltage before energization to prevent exceeding the 30.0 VDC maximum allowable input limit. During cable installation, maintain separation between relay output bundles and low-level status input circuits to reduce transient coupling into the digital input section.\u003c\/p\u003e\n\u003cp\u003eFor KS cable interface configurations, confirm cable locking integrity and connector seating before applying system power. Avoid repeated insertion cycles under energized backplane conditions unless explicitly permitted by the host DCS maintenance procedure.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44143081193560,"sku":"ADV151-P63\/D5A00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ADV151-P63D5A00.jpg?v=1779758682","url":"https:\/\/www.industriaxplc.com\/products\/digital-input-module-adv151-p63-d5a00-yokogawa","provider":"IndustriaX Limited","version":"1.0","type":"link"}