{"product_id":"deltav-sseries-fm21ukex0017u-terminal-block-emerson","title":"DeltaV SSeries FM21UKEX0017U Terminal Block | Emerson","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeltaV SSeries Terminal Block (FM21UKEX0017U)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for reliable operation in hazardous environments. Designed for use with Zone 2 installations, it ensures secure connectivity and compliance with international safety standards. This terminal block is compatible with a wide range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeltaV SSeries I\/O cards\u003c\/strong\u003e, featuring a rotary keying system that guarantees proper card alignment and system integrity.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupply Voltage: 30 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Consumption: 200 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -40°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShock Resistance: 10 g, 11 ms half-sine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration Tolerance: 1 mm peak-to-peak from 2–13.2 Hz; 0.7 g from 13.2–150 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity: 5–95%, non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAirborne Contaminants: Class G3 per ISA-S71.04-1985\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous Atmosphere:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEx ec nC IIC Gc\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFM Approvals: FM19ATEX0173U, FM17US0286U, FM17CA0145U, FM21UKEX0017U\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIECEx: FMG 19.0019U\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClass I, Division 2, Groups A, B, C, D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClass I, Zone 2, AEx\/Ex ec nC IIC Gc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation \u0026amp; Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal blocks can be installed or removed with system power applied only when no I\/O card is present and no field wiring is connected\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotary keying system ensures proper card compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKeys must be set according to the specific I\/O card used\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNo user-serviceable parts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisassembly is not permitted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration is not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eIdeal for use in process automation systems, hazardous area signal interfacing, and distributed control environments where compliance with Zone 2 \/ Class I Division 2 safety standards is required.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the terminal block be installed while the system is powered?\u003c\/strong\u003e\u003cbr\u003eA: Yes, but only if no I\/O card is installed and field wiring is disconnected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this product require calibration?\u003c\/strong\u003e\u003cbr\u003eA: No calibration is necessary for operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which I\/O cards are compatible?\u003c\/strong\u003e\u003cbr\u003eA: Compatibility is ensured through the rotary keying system; keys must match the I\/O card type.\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":44054496280664,"sku":"KJ4006X1-BT1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/EmersonKJ4006X1-BT1-3.jpg?v=1777532930","url":"https:\/\/www.industriaxplc.com\/products\/deltav-sseries-fm21ukex0017u-terminal-block-emerson","provider":"IndustriaX Limited","version":"1.0","type":"link"}