{"product_id":"deltav-m-series-fm17us0286u-emerson-zone-2-hazardous-controller","title":"DeltaV M-Series FM17US0286U Emerson Zone 2 Hazardous Controller","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeltaV M-Series (FM17US0286U)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom Emerson is engineered for safe operation in hazardous environments, meeting international standards for explosive atmospheres. Designed for Zone 2\/Division 2 applications, it ensures reliable process control with minimal maintenance requirements.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eCertifications \u0026amp; Hazardous Area Ratings\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eII 3G Ex ec IIC Gc\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– ATEX Certified (FM16ATEX0056U \/ FM21UKEX0017U)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClass I Division 2 Groups A, B, C, D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– North American Standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZone 2 AEx\/Ex ec IIC Gc\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– IECEx Certified (FM17US0286U \/ FM17CA0145U)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese ratings confirm suitability for environments with flammable gases, vapors, and dust, providing safe operation under strict regulatory requirements.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eElectrical \u0026amp; Power Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLocal Bus Power: 12.6 VDC at 8 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower must be de-energized before any module removal or connection changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports system operation under full-rated power within hazardous area limits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eInstallation \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFollow\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeltaV™ Scalable Process System Zone 2 Installation Instructions\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Document 12P2046)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem power must be off during insertion or removal of modules in hazardous areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-serviceable; do not disassemble\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo calibration required for standard operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eIdeal for process industries requiring reliable distributed control in hazardous environments, such as: chemical, oil \u0026amp; gas, and refining sectors. Supports integration into scalable DeltaV systems for automated process monitoring and control.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be inserted with power on?\u003c\/strong\u003e\u003cbr\u003eA: No. Insertion or removal must occur only in a non-hazardous, de-energized state.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this unit require periodic calibration?\u003c\/strong\u003e\u003cbr\u003eA: No calibration is needed. The unit is factory-configured for operation within specified parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does it differ from FM16ATEX0056U?\u003c\/strong\u003e\u003cbr\u003eA: FM17US0286U is designed for US and Canadian hazardous area certifications with Zone 2\/Div. 2 compliance, while FM16ATEX0056U focuses on ATEX Zone 2 certification.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications Table\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e10 g, ½ sinewave, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e1 mm P-P (2–13.2 Hz), 0.7 g (13.2–150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5–95% Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirborne Contaminants\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Bus Power\u003c\/td\u003e\n\u003ctd\u003e12.6 VDC at 8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Rating\u003c\/td\u003e\n\u003ctd\u003eII 3G Ex ec IIC Gc, Class I Div 2, Zone 2 AEx\/Ex ec IIC Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance\u003c\/td\u003e\n\u003ctd\u003eNo user-serviceable parts, calibration not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":44074139910232,"sku":"VS6002 KJ2221X1-EA1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/EmersonVS6002KJ2221X1-EA1.jpg?v=1778132875","url":"https:\/\/www.industriaxplc.com\/products\/deltav-m-series-fm17us0286u-emerson-zone-2-hazardous-controller","provider":"IndustriaX Limited","version":"1.0","type":"link"}