{"product_id":"contact-output-module-yokogawa-f3yc08-0c-fa-m3","title":"Contact Output Module | Yokogawa F3YC08-0C FA-M3","description":"\u003ch2\u003eYokogawa F3YC08-0C FA-M3 Contact Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa F3YC08-0C\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3YC08-0C\u003c\/strong\u003e Contact Output Module, operates as a dedicated hardware component for switching discrete field devices within the FA-M3 PLC system.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa F3YC08-0C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e170 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FA-M3 module size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e75 mA typical at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputType\u003c\/td\u003e\n\u003ctd\u003eNo-voltage contact, relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumberOfOutputs\u003c\/td\u003e\n\u003ctd\u003e8 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximumSwitchingVoltage\u003c\/td\u003e\n\u003ctd\u003e250 V AC, 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximumSwitchingCurrent\u003c\/td\u003e\n\u003ctd\u003e2 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommonConfiguration\u003c\/td\u003e\n\u003ctd\u003eSeparate common per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolationMethod\u003c\/td\u003e\n\u003ctd\u003eTransformer isolation for each input\/output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eONResistance\u003c\/td\u003e\n\u003ctd\u003eMax 200 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFFResistance\u003c\/td\u003e\n\u003ctd\u003eMin 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputResponseTime\u003c\/td\u003e\n\u003ctd\u003eConfigurable: 0 μs, 62.5 μs, 250 μs, 1 ms, 16 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminalType\u003c\/td\u003e\n\u003ctd\u003e10-point M3.5 screw detachable block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eEach output point is independently isolated via relay contacts, allowing simultaneous control of mixed-voltage AC and DC devices. The mechanical isolation ensures no cross-talk occurs between channels. This isolation also protects the PLC backplane from voltage transients originating in field wiring. The module design is compatible with 4-20 mA HART loop systems, maintaining signal integrity across industrial process networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module be hot-swapped during operation?\u003c\/strong\u003e\u003cbr\u003eA: The detachable terminal block allows for replacement of the module without disconnecting field wiring, but only when the PLC is in a safe standby state. Energized outputs should be considered live.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum simultaneous ON ratio for outputs?\u003c\/strong\u003e\u003cbr\u003eA: The module supports up to 100% of outputs turned on simultaneously, within thermal limits defined by Yokogawa.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the input response time configured?\u003c\/strong\u003e\u003cbr\u003eA: Response time can be set via the PLC CPU for 0 μs, 62.5 μs, 250 μs, 1 ms, or 16 ms. Effective ON\/OFF switching delay is sampling period plus 1 ms max.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module on the FA-M3 standard DIN rail slot. Ensure proper alignment to avoid stress on connector pins.\u003c\/li\u003e\n\u003cli\u003eConnect separate commons per channel as indicated to prevent unintended current paths.\u003c\/li\u003e\n\u003cli\u003eRoute signal and power wires in separate conduits to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eUse M3.5 screws to secure field wiring to the detachable terminal block. Torque should comply with standard industrial wiring practices.\u003c\/li\u003e\n\u003cli\u003eGround module shield and surrounding metal panel to maintain EMC compliance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44163020456024,"sku":"F3YC08-0C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/F3YC08-0C.jpg?v=1780279648","url":"https:\/\/www.industriaxplc.com\/products\/contact-output-module-yokogawa-f3yc08-0c-fa-m3","provider":"IndustriaX Limited","version":"1.0","type":"link"}