{"product_id":"contact-output-module-adc32-s1-yokogawa","title":"Contact Output Module |  ADC32-S1 | Yokogawa","description":"\u003ch2\u003eYokogawa ADC32-S1 Contact Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ADC32-S1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADC32\u003c\/strong\u003e Contact Output Module, operates as a dedicated hardware component for isolated relay switching across 32 channels within ProSafe-RS safety systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa ADC32-S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6.56 cm × 7.20 cm × 5.23 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e-10 to +55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidityRange\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (Non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumberOfChannels\u003c\/td\u003e\n\u003ctd\u003e32 isolated outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputType\u003c\/td\u003e\n\u003ctd\u003eRelay contact (dry contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchConfiguration\u003c\/td\u003e\n\u003ctd\u003eOn\/Off, Sink or Source capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLEDStatusIndicators\u003c\/td\u003e\n\u003ctd\u003eYes, per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstandingVoltage\u003c\/td\u003e\n\u003ctd\u003e500 VDC to 1500 VAC, 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003ePer module nominal, refer to datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003cstrong\u003eSIS-Specific Signal Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ADC32-S1 provides galvanic isolation for all 32 output channels, ensuring separation between field wiring and internal safety logic. Each channel supports positive contact feedback to confirm switching events, maintaining compliance with SIL-rated safety loops. Channel-to-channel isolation mitigates cross-talk, allowing simultaneous switching of multiple actuators without signal interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eQ: VnA: Can the ADC32-S1 outputs drive both sourcing and sinking devices?\u003cbr\u003eA: Yes, each channel is configurable to sink or source current according to connected actuator requirements, within the rated voltage\/current limits.\u003c\/p\u003e\n\u003cp\u003eQ: VnA: What is the maximum switching voltage and current per channel?\u003cbr\u003eA: Refer to the module datasheet; typical ratings support up to 24–30 VDC for safe loop operation. Exceeding rated values may compromise isolation.\u003c\/p\u003e\n\u003cp\u003eQ: VnA: Is the ADC32-S1 suitable for hot-swapping in a live ProSafe-RS rack?\u003cbr\u003eA: No. Module insertion or removal must occur with the backplane de-energized to prevent logic or relay damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module into standard Yokogawa FIO backplane slots with firm mechanical engagement.\u003c\/li\u003e\n\u003cli\u003eEnsure all output field wiring is shielded and terminated with proper grounding to reduce EMI.\u003c\/li\u003e\n\u003cli\u003eKeep high-current and signal wiring physically separated to prevent inductive coupling.\u003c\/li\u003e\n\u003cli\u003eConfirm backplane voltage is removed before module installation or removal.\u003c\/li\u003e\n\u003cli\u003eVerify channel LED indicators illuminate correctly after installation to confirm electrical continuity.\u003c\/li\u003e\n\u003cli\u003eAvoid exceeding environmental limits of temperature and humidity; maintain non-condensing conditions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44208965812312,"sku":"ADC32 S1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ADC32S1-3.jpg?v=1780968636","url":"https:\/\/www.industriaxplc.com\/products\/contact-output-module-adc32-s1-yokogawa","provider":"IndustriaX Limited","version":"1.0","type":"link"}