{"product_id":"canopen-communication-module-yokogawa-nflc121-s00","title":"CANopen Communication Module | Yokogawa |  NFLC121-S00","description":"\u003ch2\u003eYokogawa NFLC121-S00 CANopen Communication Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for CANopen master communication in STARDOM FCN and FCN-RTU control networks, the \u003cstrong\u003eYokogawa NFLC121-S00\u003c\/strong\u003e (\u003cstrong\u003eNFLC121\u003c\/strong\u003e CANopen Communication Module) provides direct physical and protocol-level execution of cyclic and acyclic data exchange between the host controller and CANopen slave devices. The module operates through a single CANopen communication port and supports network management, PDO\/SDO messaging, and node supervision functions within controller-based automation architectures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation identifies \u003cstrong\u003eNFLC121-S00\u003c\/strong\u003e as the standard model variant. No additional suffix matrix or ordering-code decomposition is specified in the available technical data.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFLC121-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCANopen Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eCANopen (CiA 301 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRole\u003c\/td\u003e\n\u003ctd\u003eCANopen Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Ports\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eD-sub 9-pin male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e10 kbps to 1 Mbps selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Nodes\u003c\/td\u003e\n\u003ctd\u003eUp to 127 CANopen slave nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eSignal-to-system transformer isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e700 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 degC to +55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-25 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 % to 95 % RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eISA G3 corrosive gas resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Process Control Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe NFLC121-S00 incorporates transformer-based signal isolation between the communication interface and the controller system circuitry. This isolation arrangement limits the propagation of external electrical disturbances from the field communication segment into the controller backplane.\u003c\/p\u003e\n\u003cp\u003eWithin STARDOM FCN architectures, the module performs CANopen master functions including network initialization, node monitoring, PDO data transfer, SDO parameter access, and emergency message handling. Communication status and diagnostic information are available through onboard indication functions intended for maintenance and network troubleshooting activities.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the NFLC121-S00 operate as a CANopen master or slave device?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module operates as a CANopen master and manages communication with connected CANopen slave nodes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many field devices can be connected to one module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The CANopen network supports up to 127 slave nodes, subject to network design, addressing, cable length, and baud-rate constraints.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is communication isolation provided between the CANopen network and controller electronics?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The module utilizes transformer-based signal isolation between the communication interface and the system circuitry.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify compatibility between the installed FCN or FCN-RTU controller platform and the NFLC121-S00 module before insertion into the system base.\u003c\/li\u003e\n\u003cli\u003eUse CANopen-compliant network cabling and maintain proper bus termination at both physical ends of the communication segment.\u003c\/li\u003e\n\u003cli\u003eRoute communication cables separately from high-voltage power conductors, motor feeders, and switching circuits where practical.\u003c\/li\u003e\n\u003cli\u003eMaintain shield continuity according to the site grounding philosophy and controller installation manual.\u003c\/li\u003e\n\u003cli\u003eConfirm node addressing and baud-rate settings across all connected CANopen devices before network commissioning.\u003c\/li\u003e\n\u003cli\u003ePerform communication verification and diagnostic checks after installation and before placing the controller into operational service.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44223995183192,"sku":"NFLC121-S00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/NFLC121-S00-2.jpg?v=1781226633","url":"https:\/\/www.industriaxplc.com\/products\/canopen-communication-module-yokogawa-nflc121-s00","provider":"IndustriaX Limited","version":"1.0","type":"link"}