{"product_id":"bmxsdo0802-modicon-x80-discrete-output-module-schneider-electric","title":"BMXSDO0802 Modicon X80 Discrete Output Module | Schneider Electric","description":"\u003ch2\u003eSchneider Electric BMXSDO0802 Modicon X80 Discrete Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXSDO0802\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eModicon X80\u003c\/strong\u003e discrete output module, operates as a dedicated hardware component for solid-state positive safety logic switching within Modicon automation controller platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXSDO0802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e4.4 W maximum power dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Number\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Type\u003c\/td\u003e\n\u003ctd\u003eSolid state (Not isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Logic\u003c\/td\u003e\n\u003ctd\u003ePositive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (19...30 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per Channel\u003c\/td\u003e\n\u003ctd\u003e0.625 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Module\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Leakage Current\u003c\/td\u003e\n\u003ctd\u003e0.5 mA at state 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1.2 V at state 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time on Output\u003c\/td\u003e\n\u003ctd\u003e1.2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParalleling of Outputs\u003c\/td\u003e\n\u003ctd\u003eYes (2 maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Current Consumption\u003c\/td\u003e\n\u003ctd\u003e264 mA at 3.3 V DC, 15 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF Reliability\u003c\/td\u003e\n\u003ctd\u003e401208 H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Overload Protection\u003c\/td\u003e\n\u003ctd\u003eCurrent limiter and electronic circuit breaker (1.5 In \u0026lt; Id \u0026lt; 2 In)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Overvoltage Protection\u003c\/td\u003e\n\u003ctd\u003eTransil diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Short-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eExternal 2 A fuse required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eReverse mounted diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Detection Threshold\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 14 V DC (sensor fault), \u0026gt; 18 V DC (sensor OK)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tungsten Load\u003c\/td\u003e\n\u003ctd\u003e6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003e0.5\/LI^2 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Impedance Ohmic\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 48 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus LED Indicators\u003c\/td\u003e\n\u003ctd\u003e1 LED green (RUN), 1 LED green per channel (diagnostic), 1 LED red (ERR), 1 LED red (I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with the Modicon X80 backplane, utilizing high-speed bus communication synchronization to update the status of the 8 solid-state outputs. This deterministic bus integration minimizes internal propagation latency and ensures synchronous logic execution matching the main processor scan cycle.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum configuration allowed when paralleling outputs on this module?\u003c\/p\u003e\n\u003cp\u003eA: A maximum of 2 outputs can be connected in parallel to handle higher current loads, provided that the total current draw does not exceed the overall module limit of 10 A.\u003c\/p\u003e\n\u003cp\u003eQ: What mechanisms handle overcurrent and short-circuit faults on the channels?\u003c\/p\u003e\n\u003cp\u003eA: The module utilizes an internal current limiter and an electronic circuit breaker calibrated between 1.5 In and 2 In for overload states. Short-circuit conditions require the installation of an external 2 A fuse per specified guidelines.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall a mandatory 2 A external fast-acting fuse in series with the output channels to ensure proper short-circuit protection and prevent physical damage to the solid-state circuitry.\u003c\/li\u003e\n\u003cli\u003eRoute all 24 V DC field wiring away from high-voltage AC cables to minimize cross-talk and electromagnetic interference on the non-isolated positive logic channels.\u003c\/li\u003e\n\u003cli\u003eVerify that the total current load across all 8 channels does not exceed the 10 A maximum rating under peak operational conditions to prevent thermal overstress.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44273283170392,"sku":"BMXSDO0802","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/BMXSDO0802-3.jpg?v=1782290538","url":"https:\/\/www.industriaxplc.com\/products\/bmxsdo0802-modicon-x80-discrete-output-module-schneider-electric","provider":"IndustriaX Limited","version":"1.0","type":"link"}