{"product_id":"bmxddo1602-schneider-electric-modicon-x80-discrete-output-module","title":"BMXDDO1602 Schneider Electric Modicon X80 Discrete Output Module","description":"\u003ch2\u003eSchneider Electric BMXDDO1602 Modicon X80 Discrete Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for solid-state digital signal routing in Modicon X80 automation platforms, the \u003cstrong\u003eSchneider Electric BMXDDO1602\u003c\/strong\u003e (\u003cstrong\u003eBMXDDO1602\u003c\/strong\u003e Discrete Output Module) provides direct physical\/electrical execution. This module commands 16 discrete channels using positive source logic to interface directly with actuators, relays, and field contactors without intermediate mechanical degradation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Brand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard factory profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg net weight (145 g gross package weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.600 cm x 11.000 cm x 12.000 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0...60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40...85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4 W maximum power dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Current Consumption\u003c\/td\u003e\n\u003ctd\u003e79 mA at 3.3 V DC backplane power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Number\u003c\/td\u003e\n\u003ctd\u003e16 conforming to IEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Type\u003c\/td\u003e\n\u003ctd\u003eSolid state\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Logic\u003c\/td\u003e\n\u003ctd\u003ePositive (Source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (operational range 19...30 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel nominal (0.625 A maximum per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Module\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Leakage Current\u003c\/td\u003e\n\u003ctd\u003e0.5 mA at state 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1.2 V at state 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time on Output\u003c\/td\u003e\n\u003ctd\u003e1.2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParalleling of Outputs\u003c\/td\u003e\n\u003ctd\u003eSupported, 2 outputs maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eElectronic circuit breaker 1.5 In \u0026lt; Id \u0026lt; 2 In, with current limiter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eExternal 2 A fast-blow fuse required per channel\/group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated transil diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated reverse mounted diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Detection Threshold\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;14 V DC (preactuator fault), \u0026gt;18 V DC (state 0 preactuator)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tungsten Load\u003c\/td\u003e\n\u003ctd\u003e6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Impedance Ohmic\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;48 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10 MOhm at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 V AC at 50\/60 Hz for 1 minute (output\/ground \u0026amp; output\/internal logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe module features deterministic backplane bus communication velocity sync, which correlates data refresh cycles directly with the Modicon X80 controller task cycle. Bus clock synchronization guarantees low-latency execution of logic transitions across high-density physical topologies. This hardware structure utilizes specialized firmware flash compatibility paths to support online configuration changes without interrupting the broader deterministic industrial network runtime or dropping physical channel statuses during processing updates.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What happens when the electronic circuit breaker trips due to an output overload?\u003c\/p\u003e\n\u003cp\u003eA: The module activates its internal electronic circuit breaker when the current demands reach 1.5 to 2 times the nominal value. The current limiter restricts the fault current until the threshold triggers an output shutdown. A preactuator fault is flagged via the internal register when voltage falls below 14 V DC under active state demands.\u003c\/p\u003e\n\u003cp\u003eQ: Can multiple outputs be wired in parallel to drive higher current loads?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Paralleling of outputs is permitted up to a maximum of 2 channels. This arrangement allows the handling of inductive or resistive loads requiring steady-state capacities above the single-channel 0.625 A threshold, provided that total module current does not exceed the absolute 10 A upper physical limit.\u003c\/p\u003e\n\u003cp\u003eQ: What external protection is mandatory for short-circuit mitigation?\u003c\/p\u003e\n\u003cp\u003eA: While internal transil diodes handle overvoltage and electronic limiters manage overloads, a fast-acting 2 A external fuse must be installed in series with the external power distribution line to guarantee complete short-circuit isolation and prevent permanent trace damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting and Grounding:\u003c\/strong\u003e Insert the module firmly into the Modicon X80 backplane slot until the mechanical locking lever clicks into place. Ensure the backplane rack is bonded to the central functional earth (FE) busbar using a minimum 4 mm2 copper conductor to maintain the 1500 V AC isolation barrier performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Limitations:\u003c\/strong\u003e Use shielded twisted pair (STP) cabling for routing paths exceeding 30 meters or when routed through high electromagnetic noise zones. Keep 24 V DC signal lines physically separated from high-voltage AC motor drives or power infrastructure lines by a minimum distance of 100 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Installation:\u003c\/strong\u003e Install an individual 2 A fast-blow external fuse on the 24 V DC supply path powering the actuator circuits to prevent cascading overcurrent faults during direct terminal short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44269532708952,"sku":"BMXDDO1602","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/BMXDDO1602-3.jpg?v=1782204567","url":"https:\/\/www.industriaxplc.com\/products\/bmxddo1602-schneider-electric-modicon-x80-discrete-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}