{"product_id":"bmxdao1615-modicon-x80-discrete-output-module-schneider-electric","title":"BMXDAO1615 Modicon X80 Discrete Output Module Schneider Electric","description":"\u003ch2\u003eSchneider Electric BMXDAO1615 Modicon X80 Discrete Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete electrical switching in Modicon X80 backplane systems, the \u003cstrong\u003eSchneider Electric BMXDAO1615\u003c\/strong\u003e (\u003cstrong\u003eBMXDAO1615\u003c\/strong\u003e Discrete Output Module) provides direct physical execution of 16 channel triac-based AC output control across distributed PLC I\/O architectures. The module interfaces industrial field loads via isolated solid-state outputs designed for 24 to 240 V AC switching with backplane-controlled command updates and channel-level diagnostics.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eNo formal suffix segmentation is defined for BMXDAO1615 within the provided documentation. The model is treated as a single fixed-order identifier within the Modicon X80 discrete output module family.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Brand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.264 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.45 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTriac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 to 240 V AC (20 to 264 V AC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e3 A per channel (derated with temperature)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Module Current\u003c\/td\u003e\n\u003ctd\u003e10 A at 40 degC, 4 A at 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 ms resistive on\/off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus and Deterministic Output Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe Modicon X80 architecture integrates backplane bus communication with cyclic deterministic update cycles for discrete output modules. BMXDAO1615 channel states are mapped into PLC scan-driven memory exchanges, ensuring synchronized output refresh across distributed racks. Electrical isolation between field triac stages and logic-level backplane domains reduces channel cross-interference during high-density switching. Firmware-level I\/O image consistency is maintained through cyclic bus refresh aligned with Schneider Electric PLC execution tasks, supporting stable output state retention during transient scan transitions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the BMXDAO1615 support hot-swap replacement under load conditions?\u003cbr\u003eA: The module is designed for rack-based insertion; replacement under energized field load requires adherence to system shutdown or validated hot-swap procedures defined by the Modicon X80 backplane architecture.\u003c\/p\u003e\n\u003cp\u003eQ: What is the effect of channel leakage current on off-state loads?\u003cbr\u003eA: Each triac output exhibits off-state leakage up to the specified milliampere range depending on applied voltage level, which may require external bleed resistors for sensitive loads.\u003c\/p\u003e\n\u003cp\u003eQ: Can outputs be paralleled for higher current capacity?\u003cbr\u003eA: Paralleling outputs is not supported as each channel is individually current-limited and thermally derated within the module design.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure rack power is isolated before inserting or removing the module unless the system design explicitly supports controlled hot-swap. Maintain separation between AC field wiring and backplane communication wiring to avoid capacitive coupling. Use fast-blow external fusing per channel common ratings. Keep output wiring within specified voltage class insulation standards up to 240 V AC. Ground DIN rail and cabinet according to PLC system grounding topology to reduce triac switching noise coupling.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44278380822616,"sku":"BMXDAO1615France","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/BMXDAO1615-3.jpg?v=1782438927","url":"https:\/\/www.industriaxplc.com\/products\/bmxdao1615-modicon-x80-discrete-output-module-schneider-electric","provider":"IndustriaX Limited","version":"1.0","type":"link"}