{"product_id":"bmxami0800-schneider-electric-modicon-x80-analog-input-module","title":"BMXAMI0800 Schneider Electric Modicon X80 Analog Input Module","description":"\u003ch2\u003eSchneider Electric BMXAMI0800 Modicon X80 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXAMI0800\u003c\/strong\u003e serves as the primary \u003cstrong\u003eBMXAMI0800\u003c\/strong\u003e Analog Input Module utilized to execute high-level multi-channel analog-to-digital signal conversion across Modicon X80 platform networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXAMI0800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0...60 degC (32...140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Level\u003c\/td\u003e\n\u003ctd\u003eHigh level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Types\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCurrent: +\/- 20 mA, 0...20 mA, 4...20 mA\u003c\/p\u003e\n\u003cp\u003eVoltage: +\/- 10 V, +\/- 5 V, 0...10 V, 0...5 V, 1...5 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog\/Digital Conversion\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Resolution\u003c\/td\u003e\n\u003ctd\u003e15 bits + sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Conversion Resistor\u003c\/td\u003e\n\u003ctd\u003e250 Ohm (Precision: 0.1 %, Drift: -15 ppm\/degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Type\u003c\/td\u003e\n\u003ctd\u003eFirst order digital filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead Cycle Time\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFast: 1 ms + 1 ms x number of channels used\u003c\/p\u003e\n\u003cp\u003eNominal: 9 ms for 8 channels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Measurement Error\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt;= 0.08 % of full scale at 25 degC\u003c\/p\u003e\n\u003cp\u003e\u0026lt;= 0.1 % of full scale within 0...60 degC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Measurement Error\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt;= 0.15 % of full scale at 25 degC\u003c\/p\u003e\n\u003cp\u003e\u0026lt;= 0.3 % of full scale within 0...60 degC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1400 V DC between channels and ground\u003c\/p\u003e\n\u003cp\u003e1400 V DC between channels and bus\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Status\u003c\/td\u003e\n\u003ctd\u003eNon-isolated between channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Value Format\u003c\/td\u003e\n\u003ctd\u003e+\/- 10000 (default), +\/- 32000 (user scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Resistance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eVibration: 3 gn\u003c\/p\u003e\n\u003cp\u003eShock: 30 gn\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with the Modicon X80 backplane bus, utilizing high-velocity backplane communication loops to maintain deterministic data transmission. By providing 8 high-level analog channels within a single slot, the hardware optimizes I\/O density scaling for multi-channel instrumentation topographies without requiring extra rack space. This bus integration ensures synchronous acquisition cycles across all active channels, matching the firmware processing execution speed required by the host central processing unit.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support channel-to-channel isolation?\u003c\/p\u003e\n\u003cp\u003eA: No, the module inputs are non-isolated from each other. However, the hardware provides 1400 V DC galvanic isolation between the internal channels and the backplane bus, as well as between the channels and the chassis ground.\u003c\/p\u003e\n\u003cp\u003eQ: How is the conversion of current inputs managed internally?\u003c\/p\u003e\n\u003cp\u003eA: The module contains an internal 250 Ohm conversion resistor with a precision rating of 0.1 % and a low temperature drift of -15 ppm\/degC to transform incoming current loops into readable voltage steps for the 16-bit analog-to-digital converter.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Connection:\u003c\/strong\u003e Terminate all external signal wiring through the dedicated 28-way single connector. Ensure that current and voltage inputs conform strictly to the assigned terminal mapping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Regulations:\u003c\/strong\u003e Utilize twisted shielded pairs for all low-level signal lines. Connect the cable shields directly to the functional ground bar of the rack enclosure to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Clearances:\u003c\/strong\u003e Maintain standard spacing requirements around the Modicon X80 rack to allow natural thermal dissipation, ensuring ambient temperatures inside the cabinet do not exceed 60 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Protection Constraints:\u003c\/strong\u003e Do not apply signals exceeding the permitted overload thresholds (+\/- 30 mA for current loops and +\/- 30 V for voltage ranges) to prevent permanent deterioration of the internal measurement circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44269487423576,"sku":"BMXAMI0800","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/BMXAMI0800.jpg?v=1782202988","url":"https:\/\/www.industriaxplc.com\/products\/bmxami0800-schneider-electric-modicon-x80-analog-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}