{"product_id":"bently-nevada-9200-01-02-02-00-two-wire-transducer","title":"Bently Nevada 9200-01-02-02-00 Two-wire Transducer","description":"\u003ch2\u003eBently Nevada 9200-01-02-02-00 Two-wire Transducer\u003c\/h2\u003e\n\u003cp\u003eThe\u003cstrong\u003eBently Nevada 9200-01-02-02-00\u003c\/strong\u003ealso cataloged asthe\u003cstrong\u003e9200-01-02-02-00\u003c\/strong\u003eTwo-wire Transducer, operates as a dedicated hardware component for mechanical displacement signal conversion within Bently Nevada 9000\/9200 proximity measurement architecture. It provides two-wire electrical interface execution for eddy-current based gap sensing chains.\u003c\/p\u003e\n\u003ch3\u003eTechnical Summary\u003c\/h3\u003e\n\u003cp\u003eConfigured for continuous proximity transduction in Bently Nevada TSI measurement loops,the\u003cstrong\u003eBently Nevada 9200-01-02-02-00\u003c\/strong\u003e(\u003cstrong\u003e9200-01-02-02-00\u003c\/strong\u003eTwo-wire Transducer)provides direct physical\/electrical execution of shaft displacement signal conditioning via inductive coupling interface.\u003c\/p\u003e\n\u003cp\u003eThe device implements eddy-current probe scaling behavior with calibrated response mapping for proximity gap voltage interpretation, supporting standardized -10 VDC referenced measurement chains used in rotor vibration and position monitoring systems. Cross-talk suppression is achieved through controlled impedance matching within the two-wire loop topology, maintaining signal integrity under high electromagnetic interference conditions typical of turbine and compressor skids.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e9200: Base series two-wire proximity transducer platform\u003c\/li\u003e\n\u003cli\u003e01: Transducer mounting angle option (0 deg +\/- 2.5 deg, 4.5 Hz \/ 270 cpm minimum operating frequency)\u003c\/li\u003e\n\u003cli\u003e02: Connector option (side mount configuration)\u003c\/li\u003e\n\u003cli\u003e02: Mounting base option (circular base, 1\/4-28 UNF stud)\u003c\/li\u003e\n\u003cli\u003e00: No agency approvals required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 9200-01-02-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003eTwo-wire loop powered, exact consumption not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Function\u003c\/td\u003e\n\u003ctd\u003eProximity signal transduction for eddy-current based displacement measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBently Nevada TSI Eddy-Current Scaling Behavior\u003c\/h3\u003e\n\u003cp\u003eWithin Bently Nevada proximity measurement architecture, the transducer operates as part of an eddy-current probe chain where coil impedance variation is translated into proportional gap voltage response. The system supports standardized calibration behavior aligned with -10 VDC reference scaling used in rotor dynamics monitoring channels. Signal stability is maintained through loop impedance balancing and suppression of high-frequency cross-coupling effects between adjacent probe channels in multi-channel vibration systems.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the 9200-01-02-02-00 be hot-swapped in an active TSI loop?\u003c\/strong\u003e\u003cbr\u003eA1: The device is not designed for hot-swap operation. Disconnection introduces loop impedance discontinuity that invalidates gap voltage stability during active monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does connector side mount (02) affect signal integrity?\u003c\/strong\u003e\u003cbr\u003eA2: The side mount configuration changes physical routing only. Electrical characteristics remain unchanged if shield termination and grounding are maintained per system design.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is the 1\/4-28 UNF mounting interface mechanically standardized across other 9200 variants?\u003c\/strong\u003e\u003cbr\u003eA3: The 1\/4-28 UNF stud interface is a standard mechanical coupling point within the series, ensuring consistent installation torque and alignment repeatability.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain probe cable shielding continuity from transducer body to monitoring system input module.\u003c\/li\u003e\n\u003cli\u003eEnsure 1\/4-28 UNF stud engagement is mechanically stable with full thread contact to prevent micro-vibration drift.\u003c\/li\u003e\n\u003cli\u003eAvoid routing proximity signal cables parallel to high-current conductors to minimize induced noise coupling.\u003c\/li\u003e\n\u003cli\u003eVerify mounting angle alignment within specified tolerance (0 deg +\/- 2.5 deg) prior to commissioning.\u003c\/li\u003e\n\u003cli\u003eEnsure loop integrity before energizing the two-wire measurement circuit to prevent transient overvoltage conditions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44275407683672,"sku":"9200-01-02-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/9200-01-02-02-00-3.jpg?v=1782373293","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-9200-01-02-02-00-two-wire-transducer","provider":"IndustriaX Limited","version":"1.0","type":"link"}