{"product_id":"bently-nevada-3500-91-01-02-02-dual-fiber-egd-gateway-module","title":"Bently Nevada 3500\/91-01-02-02 Dual Fiber EGD Gateway Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/91-01-02-02\u003c\/strong\u003e is a dual-port fiber Ethernet communication gateway designed for the 3500 Machinery Protection System. It provides deterministic Ethernet Global Data (EGD) connectivity between the 3500 monitoring rack and external control platforms including GE Mark VI\/VIe turbine controllers, DCS, and SCADA systems.\u003c\/p\u003e\n\u003cp\u003eThis module is engineered for high-integrity, real-time data transfer in redundant or dual-network architectures. It enables continuous transmission of machine protection data, including vibration measurements, process variables, alarm conditions, and system diagnostics, over industrial fiber-optic networks.\u003c\/p\u003e\n\u003cp\u003eThe unit is installed in one front slot and one rear I\/O slot within the 3500 rack assembly.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed Ethernet Global Data (EGD) communication interface\u003c\/li\u003e\n\u003cli\u003eDual independent fiber-optic network channels\u003c\/li\u003e\n\u003cli\u003eReal-time transmission of rack and channel data\u003c\/li\u003e\n\u003cli\u003eContinuous alarm and diagnostic reporting\u003c\/li\u003e\n\u003cli\u003eSupport for redundant communication architectures\u003c\/li\u003e\n\u003cli\u003eIntegration with GE Mark VI\/VIe control systems\u003c\/li\u003e\n\u003cli\u003eRemote command and system control capability\u003c\/li\u003e\n\u003cli\u003eHot-swappable rack module design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003e3500\/91-01-02-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eEGD Communication Gateway Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSystem Platform\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eBently Nevada 3500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eEGD v2.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eTransport Layer\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eUDP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eEthernet Standard\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIEEE 802.3u\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eDual 100BASE-FX fiber ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eMT-RJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eFiber Type\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eMultimode fiber (typical installation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eCommunication Mode\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eRedundant \/ dual-network support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e7.4 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003ePower Source\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e3500 rack backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eData Communication Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eProducer Data (Outbound from Rack)\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eVibration and dynamic channel values\u003c\/li\u003e\n\u003cli\u003eSpeed and process variables\u003c\/li\u003e\n\u003cli\u003eRack and module status information\u003c\/li\u003e\n\u003cli\u003eAlarm and setpoint data\u003c\/li\u003e\n\u003cli\u003eSystem health diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eConsumer Commands (Inbound Control Signals)\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eGroup Reset\u003c\/li\u003e\n\u003cli\u003eAlarm Inhibit functions\u003c\/li\u003e\n\u003cli\u003eTrip Multiply activation\u003c\/li\u003e\n\u003cli\u003eSpecial Alarm Inhibit control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eItemSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e241.3 × 24.4 × 241.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e0.79 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eInstallation Requirement\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e1 front slot + 1 rear I\/O slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eModule Format\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eFull-height rack-mounted module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterValue\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eHumidity\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUp to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eEN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSafety Standard\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eEN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual fiber-optic Ethernet channels for redundancy\u003c\/li\u003e\n\u003cli\u003e100BASE-FX multimode fiber communication support\u003c\/li\u003e\n\u003cli\u003eDeterministic real-time EGD data exchange\u003c\/li\u003e\n\u003cli\u003eHigh immunity to electromagnetic interference\u003c\/li\u003e\n\u003cli\u003eDesigned for mission-critical turbine and compressor systems\u003c\/li\u003e\n\u003cli\u003eSeamless integration with GE control platforms\u003c\/li\u003e\n\u003cli\u003eIndustrial-grade environmental robustness\u003c\/li\u003e\n\u003cli\u003eHot-swappable maintenance design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGas turbine control and monitoring systems\u003c\/li\u003e\n\u003cli\u003eSteam turbine protection architectures\u003c\/li\u003e\n\u003cli\u003eCompressor station monitoring systems\u003c\/li\u003e\n\u003cli\u003eOil and gas production facilities\u003c\/li\u003e\n\u003cli\u003ePipeline and pumping infrastructure\u003c\/li\u003e\n\u003cli\u003ePower generation plants\u003c\/li\u003e\n\u003cli\u003eOffshore and marine rotating equipment systems\u003c\/li\u003e\n\u003cli\u003eSCADA and distributed control integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the benefit of dual fiber ports in this module?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe dual-port design supports redundant network paths or dual communication channels, improving system reliability and fault tolerance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan this module operate in redundant Ethernet architectures?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. The \u003cstrong\u003e3500\/91-01-02-02\u003c\/strong\u003e is specifically suited for redundant or dual-network EGD configurations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat type of fiber is supported?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module typically operates with multimode fiber using 100BASE-FX standards and MT-RJ connectors.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44129301364824,"sku":"3500\/91-01-02-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/350090.jpg?v=1779439887","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-3500-91-01-02-02-dual-fiber-egd-gateway-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}