{"product_id":"bently-nevada-3500-91-01-02-00-fiber-egd-gateway-module","title":"Bently Nevada 3500\/91-01-02-00 Fiber EGD Gateway Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/91-01-02-00\u003c\/strong\u003e is a fiber-optic Ethernet Global Data (EGD) communication gateway designed for integration within the 3500 Machinery Protection System. This module provides a high-reliability digital interface between the 3500 rack and external automation platforms such as GE Mark VI\/VIe turbine control systems, DCS, and SCADA networks.\u003c\/p\u003e\n\u003cp\u003eThis configuration is engineered for extended-distance communication using fiber-optic media, improving immunity to electromagnetic interference in harsh industrial environments. It enables continuous exchange of machinery protection data, alarm states, and system diagnostics in real time.\u003c\/p\u003e\n\u003cp\u003eThe module occupies one front slot and one rear I\/O slot within the 3500 rack architecture.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time Ethernet Global Data (EGD) communication\u003c\/li\u003e\n\u003cli\u003eFiber-optic industrial Ethernet data transmission\u003c\/li\u003e\n\u003cli\u003eContinuous monitoring of rack and module status\u003c\/li\u003e\n\u003cli\u003eTransfer of alarm, setpoint, and channel measurement data\u003c\/li\u003e\n\u003cli\u003eIntegration with GE turbine control platforms\u003c\/li\u003e\n\u003cli\u003eSupport for remote reset and alarm control commands\u003c\/li\u003e\n\u003cli\u003eHigh electromagnetic noise immunity for harsh environments\u003c\/li\u003e\n\u003cli\u003eHot-swappable rack module design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003e3500\/91-01-02-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eEGD Communication Gateway Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSystem Platform\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eBently Nevada 3500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eEthernet Global Data (EGD) v2.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eTransport Layer\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eUDP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eEthernet Standard\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIEEE 802.3u\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eNetwork Medium\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eFiber optic (100BASE-FX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eMT-RJ fiber interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eData Transmission Type\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eReal-time producer\/consumer model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e7.4 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003ePower Source\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e3500 rack backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eData Communication Structure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eProducer Data\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChannel measurement values\u003c\/li\u003e\n\u003cli\u003eRack and module status signals\u003c\/li\u003e\n\u003cli\u003eAlarm and warning states\u003c\/li\u003e\n\u003cli\u003eSystem health diagnostics\u003c\/li\u003e\n\u003cli\u003eConfiguration and setpoint data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eConsumer Commands\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eGroup Reset\u003c\/li\u003e\n\u003cli\u003eAlarm Inhibit functions\u003c\/li\u003e\n\u003cli\u003eTrip Multiply control\u003c\/li\u003e\n\u003cli\u003eSpecial Alarm Inhibit commands\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eItemSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e241.3 × 24.4 × 241.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e0.79 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eInstallation Requirement\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e1 front slot + 1 rear I\/O slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eFull-height 3500 rack module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterValue\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUp to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eEN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFiber-optic 100BASE-FX Ethernet communication interface\u003c\/li\u003e\n\u003cli\u003eExtended-distance transmission capability\u003c\/li\u003e\n\u003cli\u003eHigh immunity to electrical noise and interference\u003c\/li\u003e\n\u003cli\u003eReal-time EGD data exchange architecture\u003c\/li\u003e\n\u003cli\u003eHot-swappable design for maintenance flexibility\u003c\/li\u003e\n\u003cli\u003eCompatible with GE Mark VI\/VIe control systems\u003c\/li\u003e\n\u003cli\u003eReliable industrial-grade communication performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGas turbine control and monitoring systems\u003c\/li\u003e\n\u003cli\u003eSteam turbine protection platforms\u003c\/li\u003e\n\u003cli\u003eCompressor station monitoring\u003c\/li\u003e\n\u003cli\u003eOffshore oil and gas machinery systems\u003c\/li\u003e\n\u003cli\u003ePipeline pumping and transport systems\u003c\/li\u003e\n\u003cli\u003ePower generation plant integration\u003c\/li\u003e\n\u003cli\u003eIndustrial SCADA and DCS communication networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the advantage of the fiber-optic version of the 3500\/91?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe fiber-optic interface provides improved signal integrity and allows long-distance communication with strong resistance to electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan this module work with GE Mark VIe systems?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. It is designed specifically for EGD communication environments commonly used in GE turbine control systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes the module support remote control commands?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. It supports consumer-side commands such as reset, trip multiply, and alarm inhibit functions.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44129299988568,"sku":"3500\/91-01-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/350072M2.jpg?v=1779439453","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-3500-91-01-02-00-fiber-egd-gateway-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}