{"product_id":"bently-nevada-3500-91-01-01-00-egd-gateway-module","title":"Bently Nevada 3500\/91-01-01-00 EGD Gateway Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/91-01-01-00\u003c\/strong\u003e is an Ethernet Global Data (EGD) communication module engineered for the 3500 Machinery Protection System. It establishes a high-speed Ethernet interface between the 3500 rack and external industrial control platforms, enabling deterministic data transfer for turbine control, process automation, and machinery monitoring applications.\u003c\/p\u003e\n\u003cp\u003eDesigned for integration with GE control environments and other EGD-compatible systems, the module exchanges rack measurements, alarm states, module diagnostics, and operational parameters using producer\/consumer communication architecture over UDP\/IP Ethernet networks.\u003c\/p\u003e\n\u003cp\u003eThe gateway supports real-time industrial communication where fast data acquisition and low-latency transmission are critical for rotating equipment protection systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time EGD data communication over Ethernet\u003c\/li\u003e\n\u003cli\u003eRack-wide data acquisition from 3500 monitoring systems\u003c\/li\u003e\n\u003cli\u003eProducer\/consumer data exchange architecture\u003c\/li\u003e\n\u003cli\u003eIntegration with GE Mark VIe and compatible controllers\u003c\/li\u003e\n\u003cli\u003eContinuous transmission of dynamic and static machinery data\u003c\/li\u003e\n\u003cli\u003eRemote alarm handling and rack command support\u003c\/li\u003e\n\u003cli\u003eDual-speed Ethernet network compatibility\u003c\/li\u003e\n\u003cli\u003eIndustrial-grade environmental and EMC compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003e3500\/91-01-01-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eEGD Communication Gateway Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSystem Platform\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eBently Nevada 3500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eEGD v2.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eEthernet Protocol\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eUDP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eEthernet Standards\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIEEE 802.3, IEEE 802.3u\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eEthernet Speed\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e10 Mbps \/ 100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eNetwork Interfaces\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e10BASE-T, 100BASE-TX, optional 100BASE-FX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e7.4 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eRack Power Source\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eSupplied by 3500 rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eModule Installation\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eFront module with rear I\/O module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eNetwork Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eInterface TypeConnector\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eCopper Ethernet\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eRJ-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eFiber Ethernet (optional)\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eMT-RJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe optional fiber interface supports 100BASE-FX communication for installations requiring extended distance or enhanced electromagnetic noise immunity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eData Exchange Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module supports both producer and consumer communication functions within EGD-based control architectures.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eProducer Data\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRack operational status\u003c\/li\u003e\n\u003cli\u003eModule health information\u003c\/li\u003e\n\u003cli\u003eChannel condition monitoring\u003c\/li\u003e\n\u003cli\u003eFloating-point process variables\u003c\/li\u003e\n\u003cli\u003eAlarm setpoints\u003c\/li\u003e\n\u003cli\u003eDynamic machinery measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eConsumer Commands\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eGroup Reset\u003c\/li\u003e\n\u003cli\u003eGroup Trip Multiply\u003c\/li\u003e\n\u003cli\u003eGroup Alarm Inhibit\u003c\/li\u003e\n\u003cli\u003eGroup Special Alarm Inhibit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eItemValue\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e241.3 × 24.4 × 241.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e0.79 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eFront Slot Requirement\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e1 full-height slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eRear Slot Requirement\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e1 full-height I\/O slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eEN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIntegrated front-panel LEDs provide rapid diagnostics and communication monitoring.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eIndicatorDescription\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eOK\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eModule operating status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eTX\/RX\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eEthernet activity indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance and Certifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eStandardCompliance\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eEN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eEMC\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eEN 61000 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eMarine Certifications\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eABS, DNV-GL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eHazardous Area Support\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eCSA, ATEX, IECEx compatible systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/91-01-01-00\u003c\/strong\u003e gateway module is commonly installed in critical machinery protection systems including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGas turbine monitoring\u003c\/li\u003e\n\u003cli\u003eSteam turbine protection\u003c\/li\u003e\n\u003cli\u003ePipeline compressor stations\u003c\/li\u003e\n\u003cli\u003eLNG processing facilities\u003c\/li\u003e\n\u003cli\u003eRefinery rotating equipment\u003c\/li\u003e\n\u003cli\u003eOffshore production systems\u003c\/li\u003e\n\u003cli\u003ePower generation plants\u003c\/li\u003e\n\u003cli\u003eHigh-speed compressor trains\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eComparison: 3500\/91 vs 3500\/90\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eFeature3500\/913500\/90\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003ePrimary Communication\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eEGD Ethernet\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eModbus TCP \/ Serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eCommunication Architecture\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eProducer\/Consumer\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003ePolling-based\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eTypical Integration\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eGE Mark VIe\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003ePLC \/ DCS \/ SCADA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eNetwork Type\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eReal-time Ethernet\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eGeneral industrial communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eResponse Performance\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eHigh-speed deterministic\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eStandard monitoring communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the main purpose of the 3500\/91-01-01-00 module?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides high-speed Ethernet communication between a 3500 monitoring rack and external control systems using the EGD protocol.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes the module support fiber Ethernet connections?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Certain configurations support optional 100BASE-FX fiber-optic communication through an MT-RJ interface.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhich controllers are compatible with this gateway?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module is widely integrated with GE Mark VIe turbine controllers and other EGD-compatible automation platforms.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan the gateway receive external commands?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. The module supports consumer functions including reset commands and alarm inhibit controls.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44129297399896,"sku":"3500\/91-01-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/350091-01-01-001.jpg?v=1779440678","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-3500-91-01-01-00-egd-gateway-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}