{"product_id":"bently-nevada-3500-61-temperature-monitor-module","title":"Bently Nevada 3500\/61 Temperature Monitor Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eBently Nevada\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61 Temperature Monitor Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dedicated multi-channel monitoring solution developed for continuous thermal supervision within the 3500 Machinery Protection System.\u003c\/p\u003e\n\u003cp\u003eDesigned for rotating equipment protection, the module processes signals from RTD and thermocouple sensors to identify abnormal temperature conditions before equipment damage occurs. It is commonly deployed on turbines, motors, compressors, generators, and auxiliary process systems where accurate thermal monitoring is critical for operational reliability.\u003c\/p\u003e\n\u003cp\u003eThe module combines high-speed signal processing, programmable alarm logic, and flexible sensor configuration in a compact rack-mounted design.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSix independently configurable temperature input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with both RTD and thermocouple sensor technologies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous alarm and trip comparison processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports mixed sensor configuration per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFast update cycle for real-time machinery protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGalvanic isolation between field inputs and rack ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated buffered outputs for diagnostics and testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFront module with dedicated rear I\/O module architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eModule Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates using a dual-slot arrangement within the 3500 rack system:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMain monitoring module installed in the front rack position\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMatching I\/O interface module installed in the rear slot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis structure simplifies field wiring while maintaining reliable signal isolation and system integrity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/61\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTemperature Monitor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3500 Machinery Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Channels\u003c\/td\u003e\n\u003ctd\u003e6 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Compatibility\u003c\/td\u003e\n\u003ctd\u003e3-wire and 4-wire RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported RTDs\u003c\/td\u003e\n\u003ctd\u003ePlatinum 100 Ω, Copper 10 Ω, Nickel 120 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Inputs\u003c\/td\u003e\n\u003ctd\u003eType E, J, K, T, R, and S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1°C typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Speed\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1 second for all channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e500 Vdc channel-to-ground isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Functions\u003c\/td\u003e\n\u003ctd\u003eIndependent Alert and Danger setpoints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Delay Range\u003c\/td\u003e\n\u003ctd\u003e0.1 to 60 seconds configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffered Outputs\u003c\/td\u003e\n\u003ctd\u003eFront-panel coaxial outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Power Consumption\u003c\/td\u003e\n\u003ctd\u003e7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to +12 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e241.3 × 24.4 × 241.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module is widely used in industrial protection systems requiring stable and continuous temperature monitoring:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectric motors and generators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressors and pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical processing equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCritical bearing and winding monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSensor Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/61 platform supports multiple industrial temperature sensing technologies, allowing mixed sensor deployment across channels. This flexibility enables one module to monitor bearings, windings, stator sections, and process temperatures simultaneously.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can RTD and thermocouple sensors be used together on the same module?\u003c\/strong\u003e\u003cbr\u003eYes. Each channel can be independently configured for different supported sensor types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the purpose of the buffered output connectors?\u003c\/strong\u003e\u003cbr\u003eThe front-panel buffered outputs allow technicians to connect external diagnostic equipment without interrupting system operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is the module suitable for continuous industrial operation?\u003c\/strong\u003e\u003cbr\u003eYes. The 3500\/61 is engineered for permanent installation in demanding industrial monitoring environments.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44124983066712,"sku":"3500\/61","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/350061.jpg?v=1779351359","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-3500-61-temperature-monitor-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}