{"product_id":"bently-nevada-3500-60-133835-01-temperature-monitoring-module","title":"Bently Nevada 3500\/60 133835-01 Temperature Monitoring Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/60 Temperature Monitoring Module (133835-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a rack-based 16-channel acquisition unit designed for continuous thermal condition supervision in rotating and stationary machinery systems. It is part of the Bently Nevada 3500 platform and provides high-density temperature acquisition with integrated diagnostics, alarm handling, and system communication.\u003c\/p\u003e\n\u003cp\u003eThe module is engineered for long-term deployment in machinery protection environments where thermal stability is critical to equipment reliability.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis module supports mixed sensor input across 16 independent channels:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRTD sensors:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePt100 (100 Ω platinum)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNi120 (nickel-based elements)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2-wire, 3-wire, and 4-wire configurations supported\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement range: approximately –200 °C to +850 °C (sensor dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eThermocouples:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTypes supported: J, K, E, T, R, S, B, N\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtended range capability up to ~1700 °C depending on thermocouple type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInternal automatic cold-junction compensation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eInput characteristics:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRTD input impedance \u0026gt; 1 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermocouple input impedance \u0026gt; 10 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement and Diagnostic Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEach channel operates independently and provides:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous temperature acquisition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual alarm thresholds per channel (warning and critical levels)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOpen-circuit detection for broken sensor wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShort-circuit and wiring fault identification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannel-level configuration flexibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData trending and historical logging through rack communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Integration and Outputs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e16-channel data transmitted through 3500 rack backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterface compatibility with TDI modules and System Display units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelay-based alarm outputs managed through external 3500\/32 or 3500\/33 modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFront-panel indicators:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSystem status (OK)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication activity (TX\/RX)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBypass condition indication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo direct analog buffering is provided, as temperature data is handled digitally within the rack architecture.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAccuracy and Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRTD measurement accuracy: ±0.1% of reading\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermocouple accuracy: typically ±1 °C to ±2 °C depending on type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement resolution: 0.1 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannel update interval: approximately 100 ms per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese characteristics support stable long-term monitoring in thermally dynamic machinery environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical and Environmental Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTypical power consumption: 7.0 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature range: –30 °C to +65 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative humidity tolerance: up to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompliance:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCE certified\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCSA certified\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAPI 670 compliant system integration capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine casing and bearing temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressor thermal supervision\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMotor and generator winding temperature tracking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGearbox and lubrication system thermal monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePump system condition tracking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Does this module support both RTD and thermocouples simultaneously?\u003c\/strong\u003e\u003cbr\u003eYes, each of the 16 channels can be configured individually for RTD or thermocouple input.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is signal conditioning required externally?\u003c\/strong\u003e\u003cbr\u003eNo, cold-junction compensation and signal conditioning are integrated into the module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How are alarms handled?\u003c\/strong\u003e\u003cbr\u003eAlarm thresholds are configured per channel and communicated through the 3500 rack system to relay modules.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44112771416152,"sku":"3500\/60 133835-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/350060133835-01.jpg?v=1779185170","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-3500-60-133835-01-temperature-monitoring-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}