{"product_id":"bently-nevada-3500-22m-146031-02-transient-data-interface-module","title":"Bently Nevada 3500\/22M 146031-02 Transient Data Interface Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 3500\/22M\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e146031-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransient Data Interface is a rack-level communication processor designed for the 3500 machinery protection architecture. This version integrates fiber-optic Ethernet capability, providing enhanced signal integrity and extended transmission distance for critical monitoring networks.\u003c\/p\u003e\n\u003cp\u003eIt functions as the primary data coordination node for the rack, consolidating configuration control, real-time communication, and vibration data acquisition into a unified interface connected to System 1 software.\u003c\/p\u003e\n\u003cp\u003eUnlike protection modules, this unit operates outside the safety trip circuit, ensuring that machinery protection remains fully active even if communication hardware is offline.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Function Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentral processing interface for Bently Nevada 3500 rack communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAggregates steady-state, dynamic, and transient vibration datasets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSynchronizes data streams across all compatible monitoring modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStores and manages rack configuration parameters locally\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstalled in Slot 1 of the rack backplane system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis variant introduces dual Ethernet paths:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePrimary interface: 100Base-FX fiber-optic Ethernet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecondary interface: 10\/100Base-TX copper Ethernet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUSB Type-B port for local configuration and diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuto-negotiation support for copper Ethernet channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSupported communication functions:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-resolution transient waveform transmission\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous vibration data streaming\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem 1 condition monitoring integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRack configuration upload and download operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModbus TCP communication support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe fiber-optic interface improves resistance to electromagnetic interference and enables stable communication over long distances, making it suitable for electrically noisy environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower consumption: 10.5 W (supplied via rack backplane)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating mode: Normally energized architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOK relay output (via I\/O module):\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRated 5 A @ 24 VDC \/ 120 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum load: 120 W \/ 600 VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGold-plated contacts for low-current reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum switching capability: 1 mA @ 1 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated arc suppression design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFront Panel Controls \u0026amp; Indicators\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOK LED: Module operational status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTX\/RX LED: Network communication activity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCONFIG OK LED: Configuration validation status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTM LED: Trip Multiply indication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRack Reset: Alarm clearing function\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAddress selector: Rack ID configuration (1–127 range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKey switch: RUN \/ PROGRAM operating modes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eForm factor: Full-height 3500 system module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFront installation: Slot 1 (control position)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRear assembly: Dedicated I\/O module interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApproximate dimensions:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTDI module: 241 × 24 × 242 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApproximate weights:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTDI module: 0.91 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature: -30°C to +65°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage temperature: -40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity tolerance: 0–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for continuous operation in harsh industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for offshore, refinery, petrochemical, and power generation installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eServes as the primary rack communication backbone\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports acquisition of static, dynamic, and transient vibration signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFiber-optic communication improves immunity to electrical noise\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFully compatible with System 1 diagnostic platform\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWorks with all M-series monitor modules (e.g., 3500\/40M, 3500\/42M, 3500\/45M)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHot-swappable design for maintenance without system shutdown\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the advantage of fiber-optic Ethernet in this module?\u003c\/strong\u003e\u003cbr\u003eIt provides improved noise immunity and supports longer-distance communication compared to copper Ethernet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does this module affect protection functions?\u003c\/strong\u003e\u003cbr\u003eNo. It is strictly a communication interface and does not participate in the trip protection path.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can copper Ethernet still be used?\u003c\/strong\u003e\u003cbr\u003eYes. The module includes a secondary 10\/100Base-TX interface for compatibility.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44095706038360,"sku":"3500\/22M 146031-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/146031-02-2.jpg?v=1778579642","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-3500-22m-146031-02-transient-data-interface-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}