{"product_id":"bently-nevada-3500-22-146031-02-transient-data-interface-module","title":"Bently Nevada 3500\/22 146031-02 Transient Data Interface Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M (146031-02)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Transient Data Interface module designed for the Bently Nevada 3500 machinery protection platform. It serves as the central communication and data acquisition hub for the rack, combining the functions of a rack interface unit and communication processor into a single integrated module.\u003c\/p\u003e\n\u003cp\u003eInstalled in Slot 1 of the 3500 rack, this module manages system-level communication, configuration handling, and high-speed data exchange between monitoring modules and external software systems.\u003c\/p\u003e\n\u003cp\u003eThis version features fiber-optic Ethernet connectivity, making it suitable for electrically noisy or long-distance industrial installations.\u003c\/p\u003e\n\u003cp\u003eImportantly, the module operates outside the protection voting path, ensuring that a failure does not impact machinery protection functionality.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentral communication gateway for 3500 rack systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCollects steady-state, dynamic, and transient vibration data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnables high-speed integration with System 1 software platform\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports full rack configuration upload and download\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterfaces with all M-series monitoring modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides diagnostic and system health communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintains independence from protection logic path\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eInterface\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Ethernet\u003c\/td\u003e\n\u003ctd\u003e100Base-FX Fiber Optic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Ethernet\u003c\/td\u003e\n\u003ctd\u003e10\/100Base-TX Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Port\u003c\/td\u003e\n\u003ctd\u003eUSB-B for configuration access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Negotiation\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Sensing\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFiber-optic communication provides enhanced immunity to electrical noise and supports extended transmission distances in industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eProvided via 3500 rack backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Function\u003c\/td\u003e\n\u003ctd\u003eCommunication and data interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Role\u003c\/td\u003e\n\u003ctd\u003eNon-protective system component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOK Relay Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e5 A @ 24 VDC \/ 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load\u003c\/td\u003e\n\u003ctd\u003e120 W \/ 600 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Switching Load\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 1 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Type\u003c\/td\u003e\n\u003ctd\u003eGold-plated contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eArc suppression included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Mode\u003c\/td\u003e\n\u003ctd\u003eNormally energized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eFront Panel Indicators \u0026amp; Controls\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eIndicator\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOK LED\u003c\/td\u003e\n\u003ctd\u003eSystem operational status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX\/RX LED\u003c\/td\u003e\n\u003ctd\u003eCommunication activity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTM LED\u003c\/td\u003e\n\u003ctd\u003eTrip Multiply status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCONFIG OK LED\u003c\/td\u003e\n\u003ctd\u003eValid configuration status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eControl\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Reset Button\u003c\/td\u003e\n\u003ctd\u003eClears latched alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddress Switch\u003c\/td\u003e\n\u003ctd\u003eRack address configuration (1–127)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKey Switch\u003c\/td\u003e\n\u003ctd\u003eRUN \/ PROGRAM mode selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/22M (146031-02)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eTransient Data Interface (TDI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Location\u003c\/td\u003e\n\u003ctd\u003eSlot 1 of 3500 rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e241.3 × 24.4 × 241.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eFront module with rear I\/O interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for harsh industrial conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for power plants, refineries, compressors, and turbine systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh resistance to electrical noise and vibration environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Role\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWithin the 3500 system architecture, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M (146031-02)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the primary data and communication hub. It:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAggregates machine condition data across all modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnables real-time transient event capture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides secure communication with System 1 software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports remote diagnostics and system configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures separation from safety and protection logic functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module required for system protection?\u003c\/strong\u003e\u003cbr\u003eNo. It supports communication and data acquisition only and does not participate in protection decisions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat advantage does fiber optic communication provide?\u003c\/strong\u003e\u003cbr\u003eIt improves noise immunity and supports long-distance, high-speed data transmission in harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the system operate without this module?\u003c\/strong\u003e\u003cbr\u003eYes, but advanced data acquisition and System 1 integration will not be available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eYes, it can be replaced without shutting down the rack under normal operating conditions.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44095690244184,"sku":"3500\/22 146031-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/146031-02.jpg?v=1778578259","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-3500-22-146031-02-transient-data-interface-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}