{"product_id":"bently-nevada-3500-15-power-supply-module-for-3500-rack","title":"Bently Nevada 3500\/15 Power Supply Module for 3500 Rack","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/15\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower supply module is designed for use within the 3500 Machinery Protection System, delivering regulated operating power to monitoring and protection modules installed in the rack. The unit supports universal AC input, high-voltage DC input, and low-voltage DC input configurations depending on the associated Power Input Module (PIM).\u003c\/p\u003e\n\u003cp\u003eAs a rack-mounted half-height module, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/15\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einstalls in the dedicated left-side power supply slots of the 3500 rack assembly. The module converts external incoming power into stabilized internal voltages required by vibration monitoring, relay, communication, and protection modules throughout the system.\u003c\/p\u003e\n\u003cp\u003eThe power supply supports both standalone and redundant configurations. In dual-supply installations, the lower module operates as the primary source while the upper module functions as backup redundancy. This arrangement enables uninterrupted rack operation during module replacement or power source failure when the secondary supply remains active.\u003c\/p\u003e\n\u003cp\u003eDesigned for continuous industrial operation, the module is widely used in turbine monitoring systems, compressor protection platforms, petrochemical facilities, power generation plants, and critical rotating equipment applications where high system availability is required.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e3500 Machinery Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eHalf-Height Rack Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Position\u003c\/td\u003e\n\u003ctd\u003eLeft Side of 3500 Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Compatibility\u003c\/td\u003e\n\u003ctd\u003e3500\/05 Rack Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Configurations\u003c\/td\u003e\n\u003ctd\u003eSingle or Dual Redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003ePassive Internal Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Mode\u003c\/td\u003e\n\u003ctd\u003eContinuous Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Voltage Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eInput Type\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eElectrical Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniversal AC Input\u003c\/td\u003e\n\u003ctd\u003e85–264 Vac RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area AC Range\u003c\/td\u003e\n\u003ctd\u003e85–250 Vac RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Frequency\u003c\/td\u003e\n\u003ctd\u003e47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak AC Input\u003c\/td\u003e\n\u003ctd\u003e120–373 Vac Peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Voltage DC Input\u003c\/td\u003e\n\u003ctd\u003e88–140 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Voltage DC Input\u003c\/td\u003e\n\u003ctd\u003e20–30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eCurrent Capacity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003ePower Configuration\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMaximum Current\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniversal AC Supply\u003c\/td\u003e\n\u003ctd\u003e2.8 A RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Voltage DC Supply\u003c\/td\u003e\n\u003ctd\u003e2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Voltage DC Supply\u003c\/td\u003e\n\u003ctd\u003e11.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated undervoltage protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOvervoltage protection through Power Input Module fuse isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous rack power support during redundant supply switchover\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStable voltage regulation for critical monitoring modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/15\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule operates with compatible Power Input Modules designed for specific AC or DC input types. Universal AC versions are not interchangeable with legacy AC PIM assemblies, while high-voltage and low-voltage DC variants require matching DC PIM configurations.\u003c\/p\u003e\n\u003cp\u003eMixed legacy and updated module\/PIM combinations may be installed within the same rack if properly matched according to system configuration requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTypical installations include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbine monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressor protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil and gas processing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotating equipment monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess control protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial vibration monitoring networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eCan the 3500\/15 operate in redundant mode?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eYes. Two power supply modules may be installed in one rack for automatic redundancy. The backup supply maintains rack operation if the primary module is removed or fails.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eWhich rack systems support the 3500\/15 module?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe module is designed for use with compatible 3500\/05 rack assemblies, including 19-inch rack and bulkhead mounting configurations.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eDoes the module support both AC and DC input power?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eYes. Depending on the selected Power Input Module, the unit supports universal AC, high-voltage DC, or low-voltage DC input operation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44095624380504,"sku":"3500\/15","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/3500_15.jpg?v=1778573397","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-3500-15-power-supply-module-for-3500-rack","provider":"IndustriaX Limited","version":"1.0","type":"link"}