{"product_id":"bently-nevada-3500-15-01-01-00-ac-power-supply-module","title":"Bently Nevada 3500\/15-01-01-00 AC Power Supply Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/15-01-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a low-voltage AC power supply designed for the Bently Nevada 3500 Series Machinery Protection System. This half-height module installs into the dedicated power supply section on the left side of the rack and delivers regulated operating power to all installed monitoring and communication modules.\u003c\/p\u003e\n\u003cp\u003eThe module operates together with a compatible Low-Voltage AC Power Input Module (PIM), accepting standard industrial AC input and converting it into stable internal DC voltages required by the rack system.\u003c\/p\u003e\n\u003cp\u003eThe 3500 rack supports either a single power supply configuration or a redundant arrangement with dual supplies. In redundant mode, the lower position functions as the primary supply while the upper position acts as the backup source. Power modules can be replaced during operation without shutting down the rack when redundancy is configured.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with Bently Nevada 3500 Series racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports redundant power supply architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHot-swappable in dual-supply installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFront-panel “Supply OK” LED indication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for continuous industrial monitoring applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated protection against undervoltage and input abnormalities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStable output distribution to all rack modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/15-01-01-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLow-Voltage AC Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85 to 132 Vac RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e110 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Rack Load Current\u003c\/td\u003e\n\u003ctd\u003e4.5 A RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Rating\u003c\/td\u003e\n\u003ctd\u003e95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eFront-panel LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Mounting\u003c\/td\u003e\n\u003ctd\u003eLeft-side rack power supply slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap Capability\u003c\/td\u003e\n\u003ctd\u003eSupported in redundant configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply Module Dimensions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eItem\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e120.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e50.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e251.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.70 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Protection Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eProtection Function\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eResponse\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUndervoltage Condition\u003c\/td\u003e\n\u003ctd\u003eNo damage to module or PIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Condition\u003c\/td\u003e\n\u003ctd\u003ePIM input fuse protection activates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/15-01-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower supply module is commonly deployed in critical rotating equipment monitoring systems including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePumps and motors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil and gas process plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeavy industrial machinery protection racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eCan the module operate in a redundant power configuration?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. The 3500 rack supports dual power supplies for redundancy. If one module fails, the secondary supply automatically maintains rack operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs the power supply hot-swappable?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module can be inserted or removed without interrupting system operation when a second redundant supply is installed and active.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat input voltage does the module require?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe unit accepts 85–132 Vac RMS input with a nominal operating voltage of 110 Vac.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhich racks are compatible with this module?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module is intended for use with Bently Nevada 3500 Series Machinery Protection System racks equipped with the corresponding low-voltage AC PIM.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44095646662744,"sku":"3500\/15-01-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/350015-01-01-00.jpg?v=1778575452","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-3500-15-01-01-00-ac-power-supply-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}