{"product_id":"bently-nevada-3500-05-01-03-05-00-01-system-rack-chassis","title":"Bently Nevada 3500\/05-01-03-05-00-01 System Rack Chassis","description":"\u003ch3\u003e\u003cstrong\u003eSystem Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/05-01-03-05-00-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a full-capacity chassis designed for the Bently Nevada 3500 machinery protection architecture. It functions as the central structural platform that houses all monitoring, relay, communication, and power modules while enabling system-wide communication and regulated power distribution through an integrated backplane.\u003c\/p\u003e\n\u003cp\u003eThis configuration is specifically engineered for installations requiring front-side wiring access, making it suitable for wall-mounted or cabinet-integrated protection systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration Definition\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis rack variant is defined by the following configuration structure:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFull-size chassis with 14 module positions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBulkhead-mount installation format with front-access wiring design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard non-barrier backplane architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo internal isolation barriers included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard EIA finish and mechanical specification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Construction \u0026amp; Access Design\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRack format: 19-inch EIA full-size chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting style: Bulkhead installation with front-access wiring layout\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrame material: Industrial-grade aluminum alloy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNominal dimensions:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHeight: ~266 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWidth: 483 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDepth: ~305 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eServiceability: All field wiring connections accessible from the front panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis design reduces rear clearance requirements and simplifies cabinet integration in constrained installations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModule Layout \u0026amp; Slot Allocation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe internal slot architecture supports structured system configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDedicated positions for core system modules:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRack Interface Module (RIM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant or single power supply units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eRemaining slots configured for:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVibration monitoring modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelay modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication interface modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe layout ensures stable communication across all installed modules via the system backplane.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical \u0026amp; Backplane System\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane type: Standard non-barrier design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower architecture: Supports redundant or single power supply configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication infrastructure:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSystem data bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelay signal bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKeyphasor and transducer signal routing channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eFull compatibility with standard Bently Nevada 3500 module range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for continuous machinery protection in API 670-compliant systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental \u0026amp; Operating Limits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature range: –20°C to +65°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage temperature range: –40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity tolerance: Up to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical resilience: Suitable for vibration-intensive industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards \u0026amp; Certifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEMC immunity: EN 61000-6-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEMC emissions: EN 61000-6-4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical safety: EN 61010-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous area approvals:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eClass I, Division 2, Groups A–D, T4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eATEX \/ IECEx Zone 2 (non-barrier configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Application Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine protection and monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressor and rotating equipment diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRefinery and petrochemical plant machinery protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWall-mounted or cabinet-integrated 3500 system installations requiring front wiring access\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the main advantage of bulkhead mounting?\u003c\/strong\u003e\u003cbr\u003eIt allows all wiring connections to be accessed from the front, reducing rear clearance requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can this rack support all 3500 modules?\u003c\/strong\u003e\u003cbr\u003eYes. It is compatible with standard Bently Nevada 3500 monitoring, relay, and communication modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is internal barrier protection included?\u003c\/strong\u003e\u003cbr\u003eNo. This configuration uses a standard non-barrier backplane design.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44093408706648,"sku":"3500\/05-01-03-05-00-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/3500_05-01-03-00-00-00_2_9830ef06-a08f-434d-bd44-90b1dae00e77.jpg?v=1778494324","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-3500-05-01-03-05-00-01-system-rack-chassis","provider":"IndustriaX Limited","version":"1.0","type":"link"}