{"product_id":"bently-nevada-3500-05-01-03-00-00-01-19-inch-system-rack-chassis","title":"Bently Nevada 3500\/05-01-03-00-00-01 19-Inch System Rack Chassis","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/05-01-03-00-00-01\u003c\/strong\u003e is a full-width 19-inch rack chassis engineered as the structural backbone of the 3500 Machinery Protection System. It provides the physical housing, electrical backplane distribution, and communication interconnection required for all monitoring, protection, and interface modules in the 3500 platform.\u003c\/p\u003e\n\u003cp\u003eThis rack serves as the central mounting platform for power supplies, monitoring modules, relay modules, communication gateways, and system interface components. It is designed for continuous operation in industrial environments requiring high reliability, modular expansion, and hot-swappable maintenance capability.\u003c\/p\u003e\n\u003cp\u003eThe configuration code “01-03-00-00-01” identifies a standard 19-inch chassis variant with factory-defined mechanical and backplane layout.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore System Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStructural mounting platform for 3500 system modules\u003c\/li\u003e\n\u003cli\u003eIntegrated backplane for power and data distribution\u003c\/li\u003e\n\u003cli\u003eCentralized communication bus architecture\u003c\/li\u003e\n\u003cli\u003eSupport for monitoring, relay, and communication modules\u003c\/li\u003e\n\u003cli\u003eHot-swappable module insertion and removal\u003c\/li\u003e\n\u003cli\u003eCompatibility with redundant power supply configurations\u003c\/li\u003e\n\u003cli\u003eIntegration into industrial control cabinet systems\u003c\/li\u003e\n\u003cli\u003eDesigned for continuous-duty machinery protection systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003e3500\/05-01-03-00-00-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e19-Inch System Rack Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSystem Platform\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eBently Nevada 3500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eRack Standard\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e19-inch EIA industrial chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSlot Capacity\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e14 module slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eBackplane Type\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIntegrated system communication + power bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eMounting Options\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003ePanel mount \/ Rack mount \/ Bulkhead mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003ePower Supply Support\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e3500\/15 AC or DC modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eRedundant Power Support\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eModule Hot Swap\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eSlot Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDedicated power supply slot(s)\u003c\/li\u003e\n\u003cli\u003eRack Interface Module (RIM) slot\u003c\/li\u003e\n\u003cli\u003e14 total module positions for system expansion\u003c\/li\u003e\n\u003cli\u003eSupport for mixed module configuration (monitoring, relay, communication)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eItemSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eWidth\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e483 mm (19-inch standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eHeight\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eApprox. 266 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eDepth\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e267–349 mm (varies by mounting style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eConstruction Material\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eIndustrial-grade aluminum alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eInstallation Orientation\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eHorizontal rack cabinet mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical System Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBackplane distributes regulated power to all installed modules\u003c\/li\u003e\n\u003cli\u003eCompatible with AC and DC power supply modules\u003c\/li\u003e\n\u003cli\u003eSupports dual-redundant power configuration\u003c\/li\u003e\n\u003cli\u003eIntegrated system-level communication bus via backplane\u003c\/li\u003e\n\u003cli\u003eContinuous operation design for mission-critical monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterValue\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e-20°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e-52°C to +105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eHumidity\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e10–90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e5–150 Hz, 2G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eShock Resistance\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e15G, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIP20 enclosure standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Integration Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/05-01-03-00-00-01\u003c\/strong\u003e rack is designed for installation in industrial control cabinets and can be configured for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFront-access wiring (bulkhead installations)\u003c\/li\u003e\n\u003cli\u003eRear-access maintenance configurations\u003c\/li\u003e\n\u003cli\u003eStandard rack-mounted enclosure systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt provides full compatibility with the complete Bently Nevada 3500 module ecosystem.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbomachinery protection systems\u003c\/li\u003e\n\u003cli\u003eOil and gas compressor monitoring systems\u003c\/li\u003e\n\u003cli\u003ePower generation control cabinets\u003c\/li\u003e\n\u003cli\u003ePipeline pumping station installations\u003c\/li\u003e\n\u003cli\u003eIndustrial rotating equipment monitoring\u003c\/li\u003e\n\u003cli\u003eOffshore and marine machinery protection systems\u003c\/li\u003e\n\u003cli\u003eSCADA-integrated monitoring infrastructures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the main purpose of the 3500\/05 rack system?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIt serves as the central chassis that mechanically supports and electrically connects all modules within the Bently Nevada 3500 machinery protection platform.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow many modules can it hold?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe rack provides 14 standard module slots, excluding dedicated positions for power supplies and the rack interface module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it support redundancy?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes, the system supports redundant power supply configurations for increased reliability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44129418805336,"sku":"3500\/05-01-03-00-00-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/350005.jpg?v=1779441961","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-3500-05-01-03-00-00-01-19-inch-system-rack-chassis","provider":"IndustriaX Limited","version":"1.0","type":"link"}