{"product_id":"bently-nevada-3300-20-01-01-02-01-00-dual-thrust-monitor","title":"Bently Nevada 3300\/16-13-01-01-00-00-00 XY\/Gap Dual Vibration Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/16 XY\/Gap Dual Vibration Monitor is a specialized rack-mounted module designed for the 3300 Monitoring System. It provides simultaneous measurement of radial shaft vibration and probe gap voltage. By continuously monitoring these parameters against user-defined alarm setpoints, the module provides critical protection for rotating machinery, including industrial turbines, centrifugal compressors, and large pumps. This unit supports predictive maintenance strategies by delivering reliable, high-resolution displacement and vibration data to the control system.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel monitoring capability for XY vibration and gap voltage.\u003c\/li\u003e\n\u003cli\u003eContinuous signal processing with integrated Alert and Danger alarm logic.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard Bently Nevada proximity probe and Proximitor sensor systems.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED status indicators for OK, Bypass, Alert, and Danger conditions.\u003c\/li\u003e\n\u003cli\u003eConfigurable output options including 4-20 mA, 1-5 VDC, and 0 to -10 VDC signals.\u003c\/li\u003e\n\u003cli\u003eDesigned for seamless integration into existing 3300 series rack environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRadial shaft vibration monitoring for fluid-film bearing machines.\u003c\/li\u003e\n\u003cli\u003eProximity probe gap voltage monitoring for machine health diagnostics.\u003c\/li\u003e\n\u003cli\u003eCritical asset protection in petrochemical, power generation, and oil and gas facilities.\u003c\/li\u003e\n\u003cli\u003eIntegration with DCS or PLC systems for automated machinery shutdown and data logging.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16-13-01-01-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Compatibility\u003c\/td\u003e\n\u003ctd\u003eProximity probes with Proximitor sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil (8 V\/mm) or 100 mV\/mil (4 V\/mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.33% typical, ±1% max at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signals\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 1-5 VDC, 0 to -10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the monitor module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eThe module must be installed in a clean, dry environment within the specified temperature range.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all transducer inputs to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the 3300 rack system per Bently Nevada installation manuals to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eVerify that all field wiring is correctly terminated at the rack backplane before applying power.\u003c\/li\u003e\n\u003cli\u003eConfirm that the configuration switches\/jumpers match the specific transducer and range requirements for the application.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/16 monitor?\u003c\/h3\u003e\u003cp\u003eThe 3300\/16 is designed to monitor radial shaft vibration and probe gap voltage simultaneously, providing essential data for machinery protection and condition monitoring.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with existing 3300 series racks?\u003c\/h3\u003e\u003cp\u003eYes, this module is specifically engineered for the 3300 rack system and is fully compatible with standard 3300 backplanes.\u003c\/p\u003e\u003ch3\u003eWhat do the status LEDs on the front panel indicate?\u003c\/h3\u003e\u003cp\u003eThe LEDs provide visual confirmation of the module's operational status, including OK (system health), Bypass (maintenance mode), and Alert\/Danger (alarm thresholds exceeded).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44673106640984,"sku":"3300\/16-13-01-01-00-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_917b63a1-cbee-4cab-92ed-8f3041d12cb0.jpg?v=1787935506","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-3300-20-01-01-02-01-00-dual-thrust-monitor","provider":"IndustriaX Limited","version":"1.0","type":"link"}