{"product_id":"bently-nevada-177896-05-3701-40-processor-module","title":"Bently Nevada 177896-05 3701\/40 Processor Module","description":"\u003ch2\u003eBently Nevada 177896-05 3701\/40 Processor Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 177896-05\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e177896-05\u003c\/strong\u003e Processor Module, operates as a dedicated hardware component for signal processing, protection logic execution, and Ethernet data communication within the ADAPT 3701\/40 Machinery Dynamics Monitor platform.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e177896-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProcessor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eADAPT 3701\/40 Machinery Dynamics Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact modular form factor; exact dimensions not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered through single or dual-redundant +24 VDC external supply via terminal base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Function\u003c\/td\u003e\n\u003ctd\u003eCentral processing unit for data acquisition, DSP, alarm evaluation, and protection logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Conversion\u003c\/td\u003e\n\u003ctd\u003e24-bit resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Range\u003c\/td\u003e\n\u003ctd\u003e110 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Bandwidth\u003c\/td\u003e\n\u003ctd\u003eUp to 40 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Mode\u003c\/td\u003e\n\u003ctd\u003eSynchronized parallel sampling across all input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Analysis\u003c\/td\u003e\n\u003ctd\u003eConfigurable synchronous and asynchronous spectrums up to 3200 lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e2 x 10Base-T\/100Base-TX auto-sensing RJ45 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus TCP, Ethernet Global Data (EGD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e6 dry contact inputs per terminal base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Protection\u003c\/td\u003e\n\u003ctd\u003eHardware configuration lock switch for Run Mode protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Configuration\u003c\/td\u003e\n\u003ctd\u003eBently Nevada Monitor Configuration (BNMC) software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eCE, North America General Safety, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Measurement and Rotor Dynamics Processing\u003c\/h3\u003e\n\u003cp\u003eThe 177896-05 Processor Module processes vibration and position signals from Bently Nevada input modules, including eddy-current proximity probes, accelerometers, velomitors, seismoprobes, dynamic pressure sensors, and Keyphasor speed inputs. Furthermore, the processor executes digital signal processing algorithms for rotor dynamics evaluation, including synchronous and asynchronous spectral analysis.\u003c\/p\u003e\n\u003cp\u003eThe module supports eddy-current probe scaling functions by processing calibrated displacement signals and maintaining measurement accuracy through sensor input conditioning. In addition, the system evaluates gap voltage conditions, including the typical -10 VDC target range used for proximity probe operation verification. Therefore, the processor provides direct monitoring of shaft displacement, vibration behavior, and machine dynamic response.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 177896-05 support redundant processor operation?\u003cbr\u003eA: Yes. When installed in a Duplex terminal base, two identical 177896-05 Processor Modules can operate in a redundant configuration. The system uses dual processors to maintain monitoring availability if one processor module becomes unavailable.\u003c\/p\u003e\n\u003cp\u003eQ: What communication interfaces are available on the processor module?\u003cbr\u003eA: The module provides two auto-sensing Ethernet ports with 10Base-T and 100Base-TX support. It communicates through Modbus TCP and Ethernet Global Data (EGD) protocols.\u003c\/p\u003e\n\u003cp\u003eQ: Which sensor signals can the processor module analyze?\u003cbr\u003eA: The processor accepts processed signals from compatible ADAPT 3701\/40 input boards, including proximity probes, accelerometers, velomitors, seismoprobes, dynamic pressure sensors, and magnetic speed pickup signals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 177896-05 Processor Module in the designated ADAPT 3701\/40 terminal base slot according to the system hardware configuration requirements. Verify that the terminal base provides the required +24 VDC supply connection before module insertion.\u003c\/p\u003e\n\u003cp\u003eMaintain proper cable separation between Ethernet communication wiring and high-current power conductors to reduce electrical interference. Use shielded sensor wiring where required and connect cable shields according to plant grounding standards.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, confirm that the proximity probe input scaling, gap voltage status, channel configuration, and alarm parameters match the installed field sensors. Keep the hardware configuration lock in the required operating position after completing commissioning changes.\u003c\/p\u003e\n\u003cp\u003eUse BNMC software to verify module communication status, input channel operation, alarm logic settings, and network communication parameters before placing the monitoring system into service.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44387388653656,"sku":"177896-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/177896-05-2.jpg?v=1784180785","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-177896-05-3701-40-processor-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}