{"product_id":"bently-nevada-172109-01-isolated-thermocouple-i-o-module","title":"Bently Nevada 172109-01 Isolated Thermocouple I\/O Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eBently Nevada\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e172109-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIsolated Tip Thermocouple I\/O Module is a temperature monitoring interface module designed for integration with Bently Nevada machinery protection and condition monitoring systems. The module provides isolated sensor input processing for thermocouple and RTD-based measurements in critical industrial equipment applications.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-noise industrial environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e172109-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincorporates isolated input circuitry to reduce electrical interference and improve signal integrity during temperature acquisition. The module is commonly deployed in turbine monitoring systems, compressor protection platforms, and rotating machinery diagnostic applications where stable temperature data is required for operational reliability.\u003c\/p\u003e\n\u003cp\u003eThe unit is compatible with Bently Nevada rack-based monitoring architectures and supports continuous thermal condition supervision across multiple measurement points.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e172109-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule converts low-level temperature sensor signals into conditioned inputs suitable for machinery monitoring and protection systems.\u003c\/p\u003e\n\u003cp\u003eCore operating features include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIsolated thermocouple input processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRTD sensor compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-channel temperature acquisition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReduced electrical noise interference\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExternal field termination support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous signal integrity monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-accuracy temperature signal conditioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with rack-based protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe isolated-tip design improves measurement stability in electrically noisy process environments such as turbines, generators, and heavy industrial machinery.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSupported Temperature Sensors\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module supports multiple industrial temperature sensing technologies used in condition monitoring systems.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eRTD Compatibility\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSensor Type\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eConfiguration Support\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePt100 Platinum RTD\u003c\/td\u003e\n\u003ctd\u003e2-wire, 3-wire, 4-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel RTD\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper RTD\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eThermocouple Compatibility\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eThermocouple Type\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eTypical Application\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eType J\u003c\/td\u003e\n\u003ctd\u003eIndustrial Process Heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType K\u003c\/td\u003e\n\u003ctd\u003eTurbine and Exhaust Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType E\u003c\/td\u003e\n\u003ctd\u003eLow-Level Signal Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType T\u003c\/td\u003e\n\u003ctd\u003eLow Temperature Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAutomatic cold-junction compensation is applied for thermocouple signal accuracy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e172109-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIsolated Tip TC I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e3500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eTSI Monitoring Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Support\u003c\/td\u003e\n\u003ctd\u003eRTD and Thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Type\u003c\/td\u003e\n\u003ctd\u003eIsolated Tip Input Design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Style\u003c\/td\u003e\n\u003ctd\u003eExternal Termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Support\u003c\/td\u003e\n\u003ctd\u003eRack System Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Applications\u003c\/td\u003e\n\u003ctd\u003eTemperature Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Condition\u003c\/td\u003e\n\u003ctd\u003eNew or Reconditioned Availability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 × 11 × 24 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe module is engineered for stable operation in industrial environments exposed to vibration, electromagnetic interference, and fluctuating thermal conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMonitoring and Protection Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e172109-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports machinery protection systems requiring accurate thermal condition monitoring for predictive maintenance and shutdown protection strategies.\u003c\/p\u003e\n\u003cp\u003eTypical monitoring functions include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBearing metal temperature supervision\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine exhaust temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGenerator winding thermal protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressor casing temperature measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess heater monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGearbox thermal condition analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial motor temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBy improving temperature signal quality and reducing interference, the module helps maintenance teams identify abnormal thermal behavior before equipment damage occurs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIndustrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module is widely used in facilities operating critical rotating and thermal process equipment.\u003c\/p\u003e\n\u003cp\u003eCommon installation environments include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas turbine control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbine monitoring platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil and gas processing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical production units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressor stations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeavy industrial machinery systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe isolated architecture is particularly valuable in applications with high electromagnetic noise or long sensor cable runs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of isolated-tip input design?\u003c\/strong\u003e\u003cbr\u003eThe isolated input architecture minimizes electrical noise and ground loop interference, improving measurement stability in industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module support both RTD and thermocouple sensors?\u003c\/strong\u003e\u003cbr\u003eYes. The module is compatible with multiple RTD and thermocouple sensor types used in machinery monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the module suitable for turbine applications?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e172109-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly installed in turbine and compressor monitoring systems where accurate temperature acquisition is critical.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module operate independently?\u003c\/strong\u003e\u003cbr\u003eNo. The module is designed for integration within compatible Bently Nevada monitoring and protection platforms.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43224509218904,"sku":"172109-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/bently-nevada-172109-01-isolated-tip-tc-i-o-module-5edo31023ag.png?v=1758527403","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-172109-01-isolated-thermocouple-i-o-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}