{"product_id":"bently-nevada-170133-050-00-internal-3300-proximitor-module","title":"Bently Nevada 170133-050-00 Internal 3300 Proximitor Module","description":"\u003ch2\u003eBently Nevada 170133-050-00 Internal 3300 Proximitor Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 170133-050-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e170133\u003c\/strong\u003e Internal Proximitor Module, operates as a dedicated signal conditioning hardware component for processing raw eddy-current probe inputs within the 1701 FieldMonitor machinery protection system.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSuffix Group\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003cth\u003eDefinition\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e170133\u003c\/td\u003e\n\u003ctd\u003eInternal 3300 Proximitor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e-050\u003c\/td\u003e\n\u003ctd\u003eCalibrated for 5.0-meter total system length (probe + extension cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption\u003c\/td\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003eStandard configuration \/ Standard scale factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e170133-050-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003eDual-channel (supports 2 proximity probes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Probes\u003c\/td\u003e\n\u003ctd\u003eStandard 3300 series 5 mm and 8 mm proximity probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e5.0 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Factor\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil (7.87 mV\/um)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e250 um to 2250 um (10 mils to 90 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Output Range\u003c\/td\u003e\n\u003ctd\u003e-1 VDC to -17 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 12.5 kHz (750,000 cpm), -3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e-24 VDC (via 1701 FieldMonitor terminal base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Target Material\u003c\/td\u003e\n\u003ctd\u003eAISI 4140 steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n\u003ctd\u003e15.2 mm (0.6 inch) diameter flat surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Shaft Diameter\u003c\/td\u003e\n\u003ctd\u003e50.8 mm (2.0 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Shaft Diameter\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 76.2 mm (3.0 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-34 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 100% condensing, non-submerged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e320 g (0.71 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature Coaxial (Click-Loc compatible, gold-plated or stainless steel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Location\u003c\/td\u003e\n\u003ctd\u003eInternal slot of Bently Nevada 1701 FieldMonitor chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe 170133 module conditions eddy-current probe signals using a nominal scale factor of 200 mV\/mil. At installation, the gap voltage should be set to target approximately -10 VDC for standard 8 mm probes with a 50 mil standoff, ensuring the operating point sits within the linear calibration window. The module's dual-channel architecture provides independent signal paths to suppress inter-channel cross-talk, maintaining measurement integrity for simultaneous radial displacement and axial position monitoring on rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 170133 module be hot-swapped in the field?\u003c\/p\u003e\n\u003cp\u003eA: No. The module must be installed or removed with the 1701 FieldMonitor chassis de-energized. The -24 VDC supply is delivered through the terminal base backplane, and live insertion may cause transient voltage spikes on adjacent channels.\u003c\/p\u003e\n\u003cp\u003eQ: What is the effect of using a probe and extension cable combination that exceeds the 5.0-meter system length?\u003c\/p\u003e\n\u003cp\u003eA: The -050 suffix calibration is valid only for a total system length of 5.0 meters. Using longer cable runs will shift the linear range and scale factor, resulting in measurement error. A different suffix variant calibrated for the actual system length must be selected.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module require external power conditioning?\u003c\/p\u003e\n\u003cp\u003eA: No. The module draws nominal -24 VDC directly from the 1701 FieldMonitor terminal base. No external power supply or conditioning equipment is required.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Mounting\u003c\/strong\u003e: Install proximity probes with the probe tip perpendicular to the target surface. Ensure the target area meets the minimum 15.2 mm diameter flat surface requirement. For shaft diameters below 76.2 mm, verify probe clearance to avoid mechanical interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Route coaxial probe cables away from power conductors and variable frequency drive (VFD) output cables to minimize electromagnetic interference. Maintain separation of at least 150 mm from high-current carrying conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Engagement\u003c\/strong\u003e: Use only Click-Loc compatible gold-plated or stainless steel connectors. Ensure the coaxial connector is fully seated and the locking mechanism is engaged. Improper seating will cause signal instability and gap voltage drift.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Voltage Verification\u003c\/strong\u003e: After installation, measure the DC gap voltage at the module terminals before applying runout compensation. The voltage should fall within the -1 VDC to -17 VDC range. A reading outside this range indicates incorrect probe-to-target distance or target material incompatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: The 1701 FieldMonitor chassis must be properly grounded per the installation manual. The coaxial cable shield should be connected to the module ground reference through the terminal base. Do not create additional ground paths at the probe end.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44320026493016,"sku":"170133-050-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/170133-050-00-3.jpg?v=1783069580","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-170133-050-00-internal-3300-proximitor-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}