{"product_id":"bently-nevada-135145-01-position-i-o-module","title":"Bently Nevada 135145-01 Position I\/O Module","description":"\u003ch1\u003eBently Nevada 135145-01 Position I\/O Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for precision position and differential expansion monitoring in 3500 Series systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 135145-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e135145-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePosition I\/O Module) provides direct electrical interface for Proximitor, Rotary Position Transducer (RPT), and DC LVDT signals.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThis unit is a fixed single-model configuration; no additional suffix or matrix decomposition applies. It supports up to four input channels with external termination blocks for connection to field sensors.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e135145-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e241.3 × 24.4 × 99.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.5 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e1–4 configurable channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccepted Inputs\u003c\/td\u003e\n\u003ctd\u003eProximitor, RPT, DC LVDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eExternal terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e-10 V to +10 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e±5000 mils (±127 mm) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Compatibility\u003c\/td\u003e\n\u003ctd\u003e3500 Series 14-slot chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eProprietary backplane protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eAPI 670, CE, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe and Position Signal Management\u003c\/h3\u003e\n\u003cp\u003eThe 135145-01 module implements eddy-current probe scaling for precise position monitoring. Gap voltage validation is maintained at -10 VDC targets, ensuring correct sensor excitation. Rotor dynamics signals are captured with \u0026lt;10 ms response per channel, while cross-talk suppression prevents interference between adjacent input channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can this module operate with both Proximitor and DC LVDT inputs simultaneously?\u003cbr\u003eA: Yes, the 135145-01 supports mixed input types across its configurable channels with independent scaling.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum response time for input channel updates?\u003cbr\u003eA: The module maintains less than 10 ms per channel for all supported input types.\u003c\/p\u003e\n\u003cp\u003eQ: Is the module compatible with 3500\/92 communication gateways?\u003cbr\u003eA: Yes, it integrates through the 3500 proprietary backplane and is fully compatible with 3500\/92 Ethernet\/RS232 gateway modules.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall in a 3500 Series rack slot with correct orientation to maintain airflow and mechanical stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect external terminations carefully to avoid loose connections; torque terminal screws to manufacturer specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure grounding of the module and shielded cables to prevent EMI affecting measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain routing separation from high-power conductors to reduce interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify input channels are configured per sensor type before system power-up.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44153347932248,"sku":"135145-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/135145-012.jpg?v=1780039080","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-135145-01-position-i-o-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}