{"product_id":"bently-nevada-130730-01-signal-input-relay-card","title":"Bently Nevada 130730-01 Signal\/Input Relay Card","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eBently Nevada 130730-01 Signal\/Input Relay Card\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 130730-01\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e130730\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignal\/input relay card, serves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal conditioning and relay execution module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilized to execute alarm, warning, and trip logic across\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500 Machinery Protection System\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatforms. It converts multi-source analog and pulse inputs into deterministic relay outputs through internal rack-based processing.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBase module: 130730 Signal\/Input Relay Card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrdering code: 130730-01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuffix “-01” defines manufacturing configuration revision\u003cbr\u003eNo additional functional segmentation or field-configurable suffix structure is defined.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e130730-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e150 mm × 100 mm × 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e–40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003eUp to 8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e4 relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0.5 V to 10 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Range\u003c\/td\u003e\n\u003ctd\u003e4 mA to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Rating\u003c\/td\u003e\n\u003ctd\u003e2 A at 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eDual Ethernet, RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e–40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5%–95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSignal Conditioning and Relay Execution Behavior\u003c\/h3\u003e\n\u003cp\u003eThe module performs analog-to-logic conversion through internal signal scaling and threshold evaluation. Input channels support mixed acquisition of vibration, Keyphasor, and process variables, with deterministic routing into relay decision blocks.\u003c\/p\u003e\n\u003cp\u003eCross-channel isolation architecture minimizes electrical coupling between input groups and relay outputs. This reduces false triggering under high EMI conditions typically present in rack-mounted TSI environments.\u003c\/p\u003e\n\u003cp\u003eRelay actuation is driven by internal logic evaluation cycles synchronized with 3500 rack bus timing. Output contact switching is limited by 2 A at 30 VDC rating envelope, ensuring controlled interface to external shutdown and alarm circuits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 130730-01 be hot-swapped in a running 3500 rack?\u003cbr\u003eA: Yes. The module supports hot-swap within 3500 rack insertion sequencing, provided system state is stable.\u003c\/p\u003e\n\u003cp\u003eQ: Do all input channels share the same reference ground?\u003cbr\u003eA: No. Input channels are electrically isolated to reduce cross-channel interference and ground loop effects.\u003c\/p\u003e\n\u003cp\u003eQ: Can relay outputs be paralleled for higher load capacity?\u003cbr\u003eA: No. Relay contacts must operate within the rated 2 A at 30 VDC limit without external paralleling.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInsert the module only into a validated 3500 rack slot with confirmed backplane alignment. Ensure full connector seating to maintain stable signal and power distribution.\u003c\/p\u003e\n\u003cp\u003eRoute input wiring (4-20 mA and voltage signals) separately from relay output wiring to reduce induced coupling. Maintain shield continuity and terminate shields at designated single-point ground locations.\u003c\/p\u003e\n\u003cp\u003eVerify correct configuration mapping for Keyphasor, vibration, and process channels prior to energization. Confirm relay state logic response during commissioning test cycles before enabling automatic trip functions.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44302174027864,"sku":"130730-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/130730-01.jpg?v=1782901944","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-130730-01-signal-input-relay-card","provider":"IndustriaX Limited","version":"1.0","type":"link"}