{"product_id":"bently-nevada-10513-02-clamp-drawer-module","title":"Bently Nevada 10513-02 Clamp Drawer Module","description":"\u003ch1\u003eBently Nevada 10513-02 Clamp Drawer Module\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 10513-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10513-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClamp Drawer Module utilized to execute machinery condition signal processing across 3300 Series Monitoring System platforms. The module interfaces with vibration, position, temperature, pressure, and overspeed monitoring channels while maintaining continuous online machinery protection functions under API 670 operating requirements.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe provided documentation references a fixed hardware configuration identified as 10513-02. No manufacturer-defined suffix variants or configurable ordering matrix were specified.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e10513-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eClamp Drawer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 Series Monitoring System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eDeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Functions\u003c\/td\u003e\n\u003ctd\u003eVibration, position, temperature, pressure, overspeed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.6 x 25.3 x 24 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance Standard\u003c\/td\u003e\n\u003ctd\u003eAPI 670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe 10513-02 module supports continuous machinery monitoring circuits where rotor dynamic response behavior must remain electrically stable during transient shaft loading conditions. Signal routing architecture within the 3300 monitoring platform assists in minimizing cross-talk propagation between adjacent vibration and position channels.\u003c\/p\u003e\n\u003cp\u003eFor eddy-current proximity monitoring applications, stable gap voltage validation relative to standard -10 VDC reference targets is required to maintain probe linearity and calibrated displacement scaling. Ground continuity and shield integrity directly affect low-level transducer signal stability during operation near rotating equipment and high-energy electrical systems.\u003c\/p\u003e\n\u003cp\u003eThe module communication interface permits integration with supervisory monitoring layers while maintaining dedicated local signal acquisition pathways for machinery protection functions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 10513-02 module support hot insertion into an energized rack?\u003c\/strong\u003e\u003cbr\u003eA: Hot-swap capability was not defined in the supplied documentation. Power isolation before module insertion or removal is recommended unless specifically permitted by the associated rack system manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of communication interface is supported by the module?\u003c\/strong\u003e\u003cbr\u003eA: The module is specified for DeviceNet communication integration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What installation practice is recommended for vibration signal wiring?\u003c\/strong\u003e\u003cbr\u003eA: Shielded instrumentation cable with single-point grounding is typically used for vibration and proximity transducer circuits to reduce electromagnetic interference and ground loop current flow.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module within a properly grounded enclosure maintaining separation between low-level transducer wiring and higher-energy power conductors. DeviceNet communication cabling should be routed independently from motor feeder circuits and variable frequency drive output wiring.\u003c\/p\u003e\n\u003cp\u003eInspect edge connectors and drawer engagement hardware before insertion into the monitoring rack. Improper seating may introduce intermittent channel communication or unstable signal reference conditions.\u003c\/p\u003e\n\u003cp\u003eMaintain shield continuity across all transducer extension wiring and avoid multi-point shield grounding practices that may introduce common-mode electrical noise into shaft vibration and axial position measurements.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44144257335384,"sku":"10513-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/10513-022.jpg?v=1779787227","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-10513-02-clamp-drawer-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}