{"product_id":"bently-nevada-102351-04-01-data-acquisition-interface-unit","title":"Bently Nevada 102351-04-01 Data Acquisition Interface Unit","description":"\u003ch3\u003eBently Nevada 102351-04-01 Data Acquisition Interface Unit\u003c\/h3\u003e\n\u003cp\u003eConfigured for synchronized multi-channel vibration data acquisition in the ADRE 208-P diagnostic platform, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 102351-04-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e102351\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eData Acquisition Interface Unit) provides direct electrical execution. The interface unit processes dynamic signals from proximity probes, accelerometers, velocity transducers, and Keyphasor inputs for rotating machinery analysis.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe provided documentation identifies 102351-04-01 as a complete configured unit for the ADRE 208-P platform. No official suffix allocation table or configurable option matrix was included in the supplied material.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e102351-04-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eData Acquisition Interface Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eADRE 208-P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 16 input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Signal Types\u003c\/td\u003e\n\u003ctd\u003eProximity probes, accelerometers, velocity transducers, dynamic pressure sensors, Keyphasor signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 20 kHz per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eRMS, peak, FFT spectral analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eEthernet, RS-485, Enhanced Parallel Port (EPP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eAC input or 24 VDC battery operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e368 x 356 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on channel loading and acquisition configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics Data Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe interface unit performs synchronous sampling across all active channels to maintain phase relationship integrity during rotor dynamic analysis. Simultaneous acquisition minimizes timing skew between vibration, Keyphasor, and pressure signals during transient machine events.\u003c\/p\u003e\n\u003cp\u003eWhen connected to eddy-current proximity probes, the unit preserves probe scaling characteristics required for shaft displacement and orbit analysis. Gap voltage stability near standard -10 VDC operating regions supports accurate waveform capture and spectral processing.\u003c\/p\u003e\n\u003cp\u003eInternal signal routing and DSP processing architecture are arranged to reduce channel cross-talk during high-frequency acquisition cycles and FFT computation tasks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 102351-04-01 operate directly from a 24 VDC field power source?\u003cbr\u003eA: Yes. The unit supports portable operation using a 24 VDC battery or compatible DC supply source.\u003c\/p\u003e\n\u003cp\u003eQ: Does the interface unit support simultaneous acquisition on all channels?\u003cbr\u003eA: Yes. The hardware performs synchronized multi-channel sampling to maintain phase correlation between measurement inputs.\u003c\/p\u003e\n\u003cp\u003eQ: Are mixed transducer types supported within the same acquisition session?\u003cbr\u003eA: Yes. The unit accepts multiple supported sensor types simultaneously, including proximity probes, accelerometers, velocity transducers, and Keyphasor inputs.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44140806930520,"sku":"102351-04-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/102351-04-012.jpg?v=1779699241","url":"https:\/\/www.industriaxplc.com\/products\/bently-nevada-102351-04-01-data-acquisition-interface-unit","provider":"IndustriaX Limited","version":"1.0","type":"link"}