{"product_id":"anr10d-420-atdoc-ndel-er-bus-node-units-yokogawa","title":"ANR10D-420\/ATDOC\/NDEL | ER Bus Node Units | Yokogawa","description":"\u003ch2\u003eYokogawa ANR10D-420\/ATDOC\/NDEL ER Bus Node Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ANR10D-420\/ATDOC\/NDEL\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eANR10D\u003c\/strong\u003e ER Bus Node Unit, operates as a dedicated hardware component for remote I\/O communication and power distribution within CENTUM VP and CENTUM CS 3000 ER Bus networks. The unit accommodates up to 8 FIO I\/O modules and transfers field I\/O data to the associated Field Control Unit (FCU) through a dual-redundant ER Bus architecture.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eANR10D\u003c\/td\u003e\n\u003ctd\u003eER Bus Node Unit, 19-inch rack-mount type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-4\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e220 to 240 V AC power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eStandard type without explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/ATDOC\u003c\/td\u003e\n\u003ctd\u003eExplosion Protection Manual included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/NDEL\u003c\/td\u003e\n\u003ctd\u003eNode Expansion License included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANR10D-420\/ATDOC\/NDEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eER Bus Node Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CENTUM CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant ER Bus via coaxial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 FIO I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNode Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 14 ER Bus Node Units per FCU (controller dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e220 to 240 V AC, single-phase, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Configuration\u003c\/td\u003e\n\u003ctd\u003eDual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e230 VA \/ 120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Terminals\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 degC to 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e10 % to 90 % RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e438 mm x 132.5 mm x 425 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Support\u003c\/td\u003e\n\u003ctd\u003eAnalog and digital FIO modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap Capability\u003c\/td\u003e\n\u003ctd\u003eSupported for power supply and installed I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Signal Isolation and Field I\/O Integration\u003c\/h3\u003e\n\u003cp\u003eWithin the CENTUM FIO architecture, the ANR10D node unit functions as the physical carrier and communication interface for distributed I\/O modules. Signal acquisition and transmission are performed by the installed FIO cards, while the node unit supplies backplane power and ER Bus communication paths.\u003c\/p\u003e\n\u003cp\u003eThe platform supports integration of process instrumentation using standard industrial signal types, including 4-20 mA loops, HART-enabled field devices, and digital process signals when corresponding FIO modules are installed. Communication redundancy is maintained through dual ER Bus channels, while module-level isolation characteristics depend on the specific FIO module configuration installed in the node chassis.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can power supply modules be replaced while the node remains operational?\u003c\/strong\u003e\u003cbr\u003eA: The unit supports online replacement of installed power supply modules when operating in the dual-redundant configuration and system maintenance procedures are followed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ANR10D directly process analog or digital field signals?\u003c\/strong\u003e\u003cbr\u003eA: No. Signal processing is performed by the installed FIO I\/O modules. The ANR10D provides module housing, backplane power distribution, and ER Bus communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the \/NDEL option a hardware feature?\u003c\/strong\u003e\u003cbr\u003eA: No. The \/NDEL suffix identifies the Node Expansion License supplied with the unit for supported FCU configurations requiring node expansion functionality.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the chassis in a 19-inch rack using the specified mounting hardware and insulation bushes.\u003c\/li\u003e\n\u003cli\u003eVerify that the incoming supply voltage matches the configured 220 to 240 V AC rating before energizing the unit.\u003c\/li\u003e\n\u003cli\u003eRoute ER Bus coaxial cables separately from high-voltage power conductors to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eMaintain proper protective grounding of the rack structure and associated field wiring shields according to plant grounding standards.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate front and rear clearance for module insertion, removal, and maintenance access.\u003c\/li\u003e\n\u003cli\u003eConfirm power redundancy wiring and ER Bus redundancy connections before commissioning.\u003c\/li\u003e\n\u003cli\u003ePerform node recognition and communication verification from the associated FCU after installation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44163653337176,"sku":"ANR10D-420\/ATDOC\/NDEL","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ANR10D-420ATDOCNDEL-2.jpg?v=1780293764","url":"https:\/\/www.industriaxplc.com\/products\/anr10d-420-atdoc-ndel-er-bus-node-units-yokogawa","provider":"IndustriaX Limited","version":"1.0","type":"link"}