{"product_id":"analog-output-iom-module-honeywell-cc-taox51","title":"Analog Output IOM Module | Honeywell | CC-TAOX51","description":"\u003ch2\u003eHoneywell CC-TAOX51 Analog Output IOM Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TAOX51\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTAOX51\u003c\/strong\u003e Analog Output IOM Module, operates as a dedicated hardware component for 4-20 mA analog output signal execution within Honeywell Experion PKS and C300 controller systems. The module provides 16 single-ended analog output channels with HART pass-through capability and conformal-coated protection for industrial installation environments.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TAOX51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal, max approximately 350 mA excluding field loop current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output IOM Module with HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS \/ C300 Controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 single-ended analog output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eHART 5, 6, and 7 pass-through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VDC system-to-field isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Resistance\u003c\/td\u003e\n\u003ctd\u003e0 to 750 Ohms at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eConformal coating, ISA-S71.04 Class G3 environment compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop and Process Control Interface\u003c\/h3\u003e\n\u003cp\u003eThe CC-TAOX51 provides analog current output channels for direct connection to field actuators, control valves, and positioners. Each output channel generates a 4-20 mA control signal and supports HART communication pass-through for device configuration, status monitoring, and diagnostic data exchange through the control system.\u003c\/p\u003e\n\u003cp\u003eThe module supports channel-to-field electrical isolation through galvanic separation and is designed for integration with Honeywell Experion PKS C300 controller I\/O architectures. The conformal-coated circuit board construction provides protection against industrial contaminants in environments classified under ISA-S71.04 Class G3.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CC-TAOX51 support redundant operation?\u003cbr\u003eA: Yes. The module supports redundant configuration within compatible Experion PKS and C300 controller architectures. The actual redundancy behavior depends on the installed I\/O configuration and controller setup.\u003c\/p\u003e\n\u003cp\u003eQ: Can the CC-TAOX51 be replaced while the system remains powered?\u003cbr\u003eA: The module supports hot-swappable replacement within compatible Honeywell I\/O architectures. Replacement procedures must follow the applicable system maintenance documentation.\u003c\/p\u003e\n\u003cp\u003eQ: What field signals are connected to the CC-TAOX51 output channels?\u003cbr\u003eA: The module provides 4-20 mA analog outputs for field devices such as control valves, actuators, and HART-enabled positioners.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the CC-TAOX51 in the designated Honeywell I\/O chassis location compatible with Experion PKS and C300 systems.\u003c\/li\u003e\n\u003cli\u003eUse the specified I\/O termination assembly for field wiring connection.\u003c\/li\u003e\n\u003cli\u003eSeparate analog signal wiring from high-voltage power and high-current switching conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eApply proper cable shielding and grounding practices according to the site instrumentation standards.\u003c\/li\u003e\n\u003cli\u003eVerify field loop polarity and output channel assignment before commissioning.\u003c\/li\u003e\n\u003cli\u003eConfirm controller configuration, channel scaling, and HART communication settings before placing the module into service.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44341008367704,"sku":"CC-TAOX51","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CC-TAOX51-3.jpg?v=1783408111","url":"https:\/\/www.industriaxplc.com\/products\/analog-output-iom-module-honeywell-cc-taox51","provider":"IndustriaX Limited","version":"1.0","type":"link"}