{"product_id":"analog-input-module-yokogawa-f3ad08-5r","title":"Analog Input Module | Yokogawa F3AD08-5R","description":"\u003ch2\u003eYokogawa F3AD08-5R Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa F3AD08-5R\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3AD08-5R\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for high-speed A\/D signal acquisition within FA-M3 PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa F3AD08-5R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e28.9 W x 100 H x 106.1 D mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 degC, 10% to 90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e210 mA @ 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e8 differential channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Voltage Ranges\u003c\/td\u003e\n\u003ctd\u003e0-5 V DC, 1-5 V DC, 0-10 V DC, -10 to 10 V DC (Default: -10 to 10 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Current Ranges\u003c\/td\u003e\n\u003ctd\u003e0-20 mA DC, 4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Maximum Rating\u003c\/td\u003e\n\u003ctd\u003e±18 V DC (Voltage), 25 mA DC (Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e≥1 MΩ for voltage, 250 Ω for current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Common-Mode Voltage\u003c\/td\u003e\n\u003ctd\u003e±1 V DC (-10 to 10 V, 0-10 V); ±6 V DC (0-5 V, 1-5 V, current ranges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Conversion Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003eVoltage: 0.4 mV; Current: 1.6 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Cycle Options\u003c\/td\u003e\n\u003ctd\u003e50 μs, 100 μs, 250 μs, 500 μs, 1 ms, 16.6 ms, 20 ms, 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% FS at 23 ±2 degC; ±0.2% FS at 0-55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScaling Capability\u003c\/td\u003e\n\u003ctd\u003eDigital range -30,000 to +30,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Method\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler isolation (between input terminals and system circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V DC for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003e18-point removable terminal block, M3.5 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eProcess Control Specific Features\u003c\/p\u003e\n\u003cp\u003eThis module supports \u003cstrong\u003echannel-to-channel isolation\u003c\/strong\u003e to prevent cross-interference between measurement lines. It is compatible with \u003cstrong\u003e4-20 mA HART loop protocol\u003c\/strong\u003e and allows integration with \u003cstrong\u003eFOUNDATION Fieldbus and Profibus PA networks\u003c\/strong\u003e. Cold junction compensation (CJC) is internally implemented for thermocouple signal stabilization, minimizing temperature-induced drift across analog channels.\u003c\/p\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: Can the F3AD08-5R module operate in hot-swap conditions?\u003cbr\u003eA: No, the module must be powered down before installation or removal to prevent signal disruption and potential backplane faults.\u003c\/p\u003e\n\u003cp\u003eQ: What is the impact of using the 50 μs conversion cycle on filtering?\u003cbr\u003eA: Digital filters (first-order lag or moving average) are bypassed during 50 μs conversion cycles; filtering is available only at cycles ≥100 μs.\u003c\/p\u003e\n\u003cp\u003eQ: How should differential signals be wired to minimize noise?\u003cbr\u003eA: Connect differential pairs twisted and shielded; ground shielding at a single point. Avoid routing parallel to high-current power cables.\u003c\/p\u003e\n\u003cp\u003eField Installation Guidelines\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the module is securely mounted on the FA-M3 backplane and properly seated in the connector.\u003c\/li\u003e\n\u003cli\u003eMaintain at least 5 mm clearance from high-voltage power lines to prevent capacitive coupling.\u003c\/li\u003e\n\u003cli\u003eTerminate analog signal shields at a single point to avoid ground loops.\u003c\/li\u003e\n\u003cli\u003eObserve correct polarity for voltage and current inputs; over-voltage beyond ratings may damage the module.\u003c\/li\u003e\n\u003cli\u003eFor multi-channel wiring, keep twisted pairs consistent and minimize length differences between positive and negative lines to preserve measurement accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44219113275480,"sku":"F3AD08-5R","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/F3AD08-5R-3.jpg?v=1781142698","url":"https:\/\/www.industriaxplc.com\/products\/analog-input-module-yokogawa-f3ad08-5r","provider":"IndustriaX Limited","version":"1.0","type":"link"}