{"product_id":"analog-input-module-schneider-electric-modicon-quantum-140aci03000","title":"Analog Input Module Schneider Electric Modicon Quantum 140ACI03000","description":"\u003ch2\u003eSchneider Electric Modicon Quantum 140ACI03000 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for signal acquisition in Modicon Quantum I\/O system, the \u003cstrong\u003eSchneider Electric Modicon Quantum Analog Input Module\u003c\/strong\u003e (\u003cstrong\u003eModicon Quantum Analog Input Module\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eNo explicit order code or suffix segmentation is provided in the source data. The module is referenced at series level as Modicon Quantum analog input hardware without additional variant identifiers.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric Modicon Quantum Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Channels\u003c\/td\u003e\n\u003ctd\u003e8 differential inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003e1-5 V, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 20 MOhm (voltage), 250 Ohm (current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1000 V DC channel-to-bus, 3000 V DC for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; -72 dB at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.05 % of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Error\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.04 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Current Requirement\u003c\/td\u003e\n\u003ctd\u003e240 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Type\u003c\/td\u003e\n\u003ctd\u003eSingle pole low pass, 3 dB at 15 Hz +\/- 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and I\/O Integration Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe Modicon Quantum analog input module interfaces through deterministic backplane communication channels within the Quantum rack architecture. Backplane bus throughput defines the 5 ms update cycle alignment between input sampling and PLC scan execution. I\/O data is mapped into 9 input words addressing space, enabling structured register-based acquisition across Schneider Electric PLC memory blocks. The module design supports stable signal acquisition under high-density rack configurations where I\/O scaling and firmware compatibility are managed at controller level.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot swap replacement during rack operation?\u003cbr\u003eA: Hot-swap capability is dependent on system rack configuration. Electrical backplane separation must be ensured prior to insertion or removal to avoid transient bus disturbance.\u003c\/p\u003e\n\u003cp\u003eQ: How is the 4-20 mA loop fault detected?\u003cbr\u003eA: The module monitors current loop continuity and flags broken wire conditions when input falls outside valid operating range thresholds.\u003c\/p\u003e\n\u003cp\u003eQ: What limits the 5 ms update time?\u003cbr\u003eA: Update time is determined by internal A\/D conversion cycle, backplane scan scheduling, and module-to-CPU communication latency.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the module is fully seated into the Quantum rack backplane connector before energizing the system. Maintain shield termination at a single-point ground to reduce differential noise coupling on 1-5 V and 4-20 mA loops. Avoid routing analog signal cables parallel to high-voltage or high-frequency switching conductors. Verify channel isolation integrity prior to commissioning, especially in multi-module rack assemblies.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44224026542168,"sku":"140ACI03000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/140ACI03000-3.jpg?v=1781230728","url":"https:\/\/www.industriaxplc.com\/products\/analog-input-module-schneider-electric-modicon-quantum-140aci03000","provider":"IndustriaX Limited","version":"1.0","type":"link"}